Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Address NEW:
293 E CROYDON PARK RD
Apply Date:
01/19/2010
Applicant:
N/A
Description:
SFR: MIRA081931 T08-M0104
Contractors:
  • MIRAMONTE ARIZONA L L C *C

Permit Reviews

Permit Number - T10CM00106
Permit Status: C of o
Permit Description: SFR: MIRA081931 T08-M0104
Start Date Submittal Complete Date Status  
01/19/2010 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 01/21/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10CM00106
Permit Status: C of o
Permit Description: SFR: MIRA081931 T08-M0104
Total Outstanding Activity Conditions - 1
Date Name
01/19/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T10CM00106
Permit Description: SFR: MIRA081931 T08-M0104
Total Completed Inspections - 22
Date Description Inspector Results Comments
01/29/2010 PLUMBING - SEWER HCS CONNECT EDURAZO Approved IVRS - Inspection :*
01/29/2010 PLUMBING - YARD WTR LINE/TEST EDURAZO Approved IVRS - Inspection :*
01/29/2010 PLUMBING - ROUGH, SOIL EDURAZO Approved IVRS - Inspection :*
02/07/2010 BUILDING PRE-SLAB EDURAZO Approved IVRS - Inspection :*
02/07/2010 EXCAVATION/LAYOUT REBAR & ZON EDURAZO Approved IVRS - Inspection :*
02/25/2010 ROOF NAILING DQUINN Approved IVRS - Inspection :*
02/25/2010 EXT METAL CLIPS/EXT SHEATHING DQUINN Approved IVRS - Inspection :*
03/24/2010 ELECTRIC - UFER DQUINN Approved IVRS - Inspection :*
03/24/2010 MECHANICAL - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
03/24/2010 ELECTRIC - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
03/24/2010 U VALUE FOR WINDOW DQUINN Approved IVRS - Inspection :*
03/24/2010 STUCCO MESH DQUINN Approved IVRS - Inspection :*
03/25/2010 PLUMBING - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
03/25/2010 FRAMING DQUINN Approved IVRS - Inspection :*
04/13/2010 SHEET ROCK NAILING EDURAZO Approved IVRS - Inspection :*
05/05/2010 ELECTRIC - CABLE DROP EDURAZO Approved IVRS - Inspection :*
06/16/2010 MECHANICAL - FINAL EDURAZO Approved IVRS - Inspection :*
06/16/2010 ELECTRIC - FINAL EDURAZO Approved IVRS - Inspection :*
06/16/2010 MECHANICAL - FINAL EDURAZO Approved IVRS - Inspection :
See detailed listing on site.| 999*
06/16/2010 ELECTRIC - FINAL EDURAZO Approved IVRS - Inspection :
See detailed listing on site.| 999*
06/17/2010 PLUMBING - FINAL EDURAZO Approved IVRS - Inspection :*
06/17/2010 BUILDING - FINAL EDURAZO Approved IVRS - Inspection :*

Documents

File Name Document Type  
C OF O_06-17-2010.TIF CERT OF OCC VIEW
None DOCUMENTS VIEW
None CONSTRPLANS VIEW