Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T09OT02789
Permit Details
Apply Date:
12/22/2009
Applicant:
PEARSON'S SIGNS *C
Description:
17688
Contractors:
- PEARSON'S SIGNS *C
Outstanding Inspections
Permit Status: Expired
Permit Number: T09OT02789
Permite Description: 17688
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/15/2010 | SIGN ELECTRIC | N/A | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) NEED SERVICE LIGHT 210.70 2) FILL UNUSED OPENINGS IN RACEWAY 3) NO PLANS OR PERMIT ON SITE |
Completed Inspections
Permit Status: Expired
Permit Number: T09OT02789
Permit Description: 17688
Total Completed Inspections - 2
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/19/2010 | SIGN SITE REVIEW | JYBARRA | Approved | |
03/15/2010 | SIGN INSPECTION | JYBARRA | Approved | IVRS - Inspection :* |