Permit Details

Status:
Expired
Type:
COMMERCIAL OTHER
Address:
5027 E 29TH ST
Apply Date:
08/25/2009
Applicant:
HARRIS KEVIN
Description:
Replace existing 2 ton package unit with a new 2 ton package unit.
Contractors:
  • HARRIS BUILDING AND DEVELOPMENT INC

Outstanding Activity Conditions

Permit Number - T09ME00538
Permit Status: Expired
Permit Description: Replace existing 2 ton package unit with a new 2 ton package unit.
Total Outstanding Activity Conditions - 1
Date Name
08/25/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T09ME00538
Permite Description: Replace existing 2 ton package unit with a new 2 ton package unit.
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
11/25/2009 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE A TRAP ON CONDENSATE DRAINS
2) TERMINATE INTO AN APPROVED LOCATION
3) USE PURPLE PRIMER ON ALL PVC FITTINGS PRIOR TO GLU
4) SLOPE ALL SECTIONS OF CONDENSATE PIPE MINIMUM 1/8" PER FT.
5) STEP UP TO 1" AFTER 1ST TEE
6) PROVIDE FRESH AIR INTAKE ON A/C UNITS
7) SUPPORT ELECTRIC DISCONNECTS
8) USE PROPER ELECTRIC FITTING AT LOW VOLTAGE CONDUIT
9) VENTS ON CONDENSATE TRAPS MUST BE DOWNSTREAM OF THE TRAP
10) PROVIDE PERMITS FOR 5029 & 5033
11) SAME NOTES FOR 4911, DO NOT MOUNT DISCONNECT TO SERVICE PANEL-UNIT OVER FUSED

Documents

File Name Document Type  
None DOCUMENTS VIEW