Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Apply Date:
12/01/2009
Applicant:
DENNIS RAY CRAFT
Description:
INSTALL:ELECTRICAL OUTLET

Permit Reviews

Permit Number - T09EL02624
Permit Status: Expired
Permit Description: INSTALL:ELECTRICAL OUTLET
Start Date Submittal Complete Date Status  
12/01/2009 ELECTRICAL 12/02/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09EL02624
Permit Status: Expired
Permit Description: INSTALL:ELECTRICAL OUTLET
Total Outstanding Activity Conditions - 1
Date Name
12/01/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T09EL02624
Permite Description: INSTALL:ELECTRICAL OUTLET
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
12/03/2009 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. CORD USED AS LIFELINE NOT RATED FOR MOBILE HOME USE.
2. WIRIGN AT SUBPANEL NOT CORRECT, HOTS & NEU NOT CONNECTED PROPERLY. COLOR CODING ON WIRES INCORRECT.
3. NO BUSHING BETWEEN UNIT & PANEL
4. IMPROPER CONNECTOR AT J-BOX ON UNIT

RECALL INSPECTION WHEN CORRECTED, USE QUALIFIED ELECTRICIAN TO DO WORK. INSTALL SMOKE DETECTORS IN UNIT.

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW