Permit: T09EL02230
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
2837 N GERONIMO AV
Address NEW:
2837 N GERONIMO AV
Apply Date:
10/05/2009
Applicant:
JAIRO GARCIA
Description:
ELECTRIC:RECONNECT RES
Outstanding Activity Conditions
Permit Number - T09EL02230
Permit Status: Expired
Permit Description: ELECTRIC:RECONNECT RES
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/05/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T09EL02230
Permite Description: ELECTRIC:RECONNECT RES
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/06/2009 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DBL LUGGING NOT ALLOWED AT PANEL (SERVICE) 2) EXPOSED WIRING IN STORE ROOM IN BACK 3) POWER OUTLET BOX ON ROOF NEEDS TO BE W/P 4) SECURITY LIGHTS AROUND HOUSE NOT WIRED TO CODE(EXPOSED SPLICES) 5) UNIT LOCKED-MUST BE OPEN FOR INSPECTION 6) RECALL INSPECTION TALK SLOW AND CLEAR WHEN LEAVING MESSAGE |
Completed Inspections
Permit Status: Expired
Permit Number: T09EL02230
Permit Description: ELECTRIC:RECONNECT RES
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/02/2009 | ELECTRIC - RECONNECT | DSANTACR | Approved | IVRS - Inspection :* |
| 11/03/2009 | TEP CLEARANCE - AM | JWEATHER | Approved | RECN CLEARED PER D. SANTACRUZ |