Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
5510 S SANTA CRUZ AV
Apply Date:
08/03/2009
Applicant:
RICHARD CUNES
Description:
RECONNECT: ELECTRIC

Outstanding Activity Conditions

Permit Number - T09EL01791
Permit Status: Expired
Permit Description: RECONNECT: ELECTRIC
Total Outstanding Activity Conditions - 1
Date Name
08/03/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T09EL01791
Permite Description: RECONNECT: ELECTRIC
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
08/05/2009 ELECTRIC - RECONNECT N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/05/2009 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED SMOKE DETECTORS BEDROOMS AND HALL PER INSTRUCTIONS
2) NEED GFCI RECEPTACLES IN BATHROOMS AND KITCHEN
3) SECURELY ATTACH PANEL TO STRUCTURE
4) EXPOSED NM CABLE AT PANEL
5) FILL UNUSED OPENING IN PANEL
6) SECURELY ATTACH COOLER BOX
7) HOOD MISSING
8) MISSING SINK-KITCHEN

Documents

File Name Document Type  
None DOCUMENTS VIEW