Permit: T09EL00025
Permit Details
Status:
Closed
Type:
SINGLE FAMILY OTHER
Address:
3433 N COUNTRY CLUB RD
Address NEW:
3433 N COUNTRY CLUB RD
Apply Date:
01/06/2009
Applicant:
CHEF JUDD
Description:
RECONNECT:ELECTRIC:SFR
Outstanding Activity Conditions
Permit Number - T09EL00025
Permit Status: Closed
Permit Description: RECONNECT:ELECTRIC:SFR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/06/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T09EL00025
Permite Description: RECONNECT:ELECTRIC:SFR
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| PERMIT FINALED | N/A | Not Inspected | ||
| 04/01/2009 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CORRECT HAZARDOUS WIRING IN MAIN DISCONNECT PANEL ON N. EXTERIOR AND IN KITCHEN SUB PANEL, KITCHEN SUB-PANEL REQUIRES GROUNDS AND NEUTRALS TO BE ISOLATED AND USE UN-POINTED SCREWS IN PANEL COVER 2) RECALL FOR FINAL WHEN ABOVE CORRECTIONS ARE COMPLETE 3) CALL TEP FOR RECONNECT ON 4/2 IN PM AT LATEST |
Completed Inspections
Permit Status: Closed
Permit Number: T09EL00025
Permit Description: RECONNECT:ELECTRIC:SFR
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/01/2009 | ELECTRIC - RECONNECT | DQUINN | Approved | IVRS - Inspection :* |
| 04/02/2009 | TEP CLEARANCE - AM | JWEATHER | Approved | RECN CLEARED PER D. QUINN |