Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Si_xpire
Type:
SINGLE FAMILY NEW
Address NEW:
7701 E BIG MEADOW DR
Apply Date:
11/18/2009
Applicant:
N/A
Description:
NEW SFR TD# LENN000357
Contractors:
  • LENNAR ARIZONA CONSTRUCTION *P *C

Permit Reviews

Permit Number - T09CM03043
Permit Status: Si_xpire
Permit Description: NEW SFR TD# LENN000357
Start Date Submittal Complete Date Status  
11/18/2009 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 11/19/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM03043
Permit Status: Si_xpire
Permit Description: NEW SFR TD# LENN000357
Total Outstanding Activity Conditions - 7
Date Name
11/18/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
11/18/2009 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)
11/18/2009 SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED.
11/18/2009 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
11/18/2009 SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED.
11/18/2009 SPECIAL INSPECTION FOR WOOD FRAMED DIAPHRAGMS AND SHEAR WALLS IS REQUIRED.
11/18/2009 SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED.

Completed Inspections

Permit Status: Si_xpire
Permit Number: T09CM03043
Permit Description: NEW SFR TD# LENN000357
Total Completed Inspections - 23
Date Description Inspector Results Comments
12/30/2009 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection :*
12/30/2009 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection :*
12/30/2009 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection :*
01/07/2010 ELECTRIC - UFER RFREIDIN Approved IVRS - Inspection :*
01/07/2010 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection :*
01/07/2010 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection :*
01/27/2010 ELECTRIC - CABLE DROP RFREIDIN Approved IVRS - Inspection :*
JOHN:
1) ALL SHOP DRAWING CALL FOR SHEATHING FOR LATERAL BRACING ON ALL FLOOR TRUSSES, WITH PLAIN VERT MEMBERS THAT SIT ON TOP OF WALLS FOR SUPPORT 20FE14 ECT...SEE DRAWINGS (FINISH TRUSS AT FRONT)
01/27/2010 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved IVRS - Inspection :*
01/28/2010 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER R. FREIDINGER
01/29/2010 ROOF NAILING RFREIDIN Approved IVRS - Inspection :*
01/29/2010 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection :*
02/09/2010 FRAMING DQUINN Approved IVRS - Inspection :*
02/09/2010 MECHANICAL - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
02/09/2010 PLUMBING - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
02/09/2010 ELECTRIC - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
02/09/2010 U VALUE FOR WINDOW DQUINN Approved IVRS - Inspection :*
02/09/2010 STUCCO MESH DQUINN Approved IVRS - Inspection :*
02/17/2010 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection :*
04/01/2010 OUTDOOR LIGHTING FINAL RFREIDIN Approved
04/01/2010 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection :*
04/01/2010 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection :*
04/01/2010 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection :*
04/01/2010 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW