Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T09CM03043
Permit Details
Status:
Si_xpire
Type:
SINGLE FAMILY NEW
Address:
7701 E BIG MEADOW DR
Address NEW:
7701 E BIG MEADOW DR
Apply Date:
11/18/2009
Applicant:
N/A
Description:
NEW SFR TD# LENN000357
Contractors:
- LENNAR ARIZONA CONSTRUCTION *P *C
Permit Reviews
Permit Number - T09CM03043
Permit Status: Si_xpire
Permit Description: NEW SFR TD# LENN000357
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/18/2009 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 11/19/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM03043
Permit Status: Si_xpire
Permit Description: NEW SFR TD# LENN000357
Total Outstanding Activity Conditions - 7
| Date | Name |
|---|---|
| 11/18/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 11/18/2009 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
| 11/18/2009 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
| 11/18/2009 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 11/18/2009 | SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED. |
| 11/18/2009 | SPECIAL INSPECTION FOR WOOD FRAMED DIAPHRAGMS AND SHEAR WALLS IS REQUIRED. |
| 11/18/2009 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
Completed Inspections
Permit Status: Si_xpire
Permit Number: T09CM03043
Permit Description: NEW SFR TD# LENN000357
Total Completed Inspections - 23
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/30/2009 | PLUMBING - SEWER HCS CONNECT | RFREIDIN | Approved | IVRS - Inspection :* |
| 12/30/2009 | PLUMBING - YARD WTR LINE/TEST | RFREIDIN | Approved | IVRS - Inspection :* |
| 12/30/2009 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/07/2010 | ELECTRIC - UFER | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/07/2010 | BUILDING PRE-SLAB | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/07/2010 | EXCAVATION/LAYOUT REBAR & ZON | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/27/2010 | ELECTRIC - CABLE DROP | RFREIDIN | Approved | IVRS - Inspection :* JOHN: 1) ALL SHOP DRAWING CALL FOR SHEATHING FOR LATERAL BRACING ON ALL FLOOR TRUSSES, WITH PLAIN VERT MEMBERS THAT SIT ON TOP OF WALLS FOR SUPPORT 20FE14 ECT...SEE DRAWINGS (FINISH TRUSS AT FRONT) |
| 01/27/2010 | ELECTRIC - TEMPORARY SERVICE | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/28/2010 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER R. FREIDINGER |
| 01/29/2010 | ROOF NAILING | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/29/2010 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | IVRS - Inspection :* |
| 02/09/2010 | FRAMING | DQUINN | Approved | IVRS - Inspection :* |
| 02/09/2010 | MECHANICAL - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 02/09/2010 | PLUMBING - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 02/09/2010 | ELECTRIC - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 02/09/2010 | U VALUE FOR WINDOW | DQUINN | Approved | IVRS - Inspection :* |
| 02/09/2010 | STUCCO MESH | DQUINN | Approved | IVRS - Inspection :* |
| 02/17/2010 | SHEET ROCK NAILING | RFREIDIN | Approved | IVRS - Inspection :* |
| 04/01/2010 | OUTDOOR LIGHTING FINAL | RFREIDIN | Approved | |
| 04/01/2010 | MECHANICAL - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
| 04/01/2010 | PLUMBING - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
| 04/01/2010 | ELECTRIC - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
| 04/01/2010 | BUILDING - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |