Permit: T09CM02414
Permit Details
Apply Date:
09/08/2009
Applicant:
N/A
Description:
ELEC REWIRE KITCHEN, REPL WATER LINES TO KITCHEN & LAUNDRY RM AND REPL W/H
Contractors:
- CULTURED STONE PRODUCTS L L C
Permit Reviews
Permit Number - T09CM02414
Permit Status: Final
Permit Description: ELEC REWIRE KITCHEN, REPL WATER LINES TO KITCHEN & LAUNDRY RM AND REPL W/H
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/08/2009 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 09/08/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM02414
Permit Status: Final
Permit Description: ELEC REWIRE KITCHEN, REPL WATER LINES TO KITCHEN & LAUNDRY RM AND REPL W/H
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/08/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T09CM02414
Permit Description: ELEC REWIRE KITCHEN, REPL WATER LINES TO KITCHEN & LAUNDRY RM AND REPL W/H
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/15/2009 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) CLEAN UP UNUSED ROMEX FROM KITCHEN 2) SECURE ALL ROMEX TO CODE 3) ALL CONDUCTORS MUST TERMINATE IN APPROVED BOXES 4) DEDICATED CIRCUITS REFRIDGERATOR, MICROWAVE, 2 EACH 15 AMP FOR APPLIANCES 5) PROVIDE 1 1/4" CLEARANCES ROMEX FOR PROTECTION MASONRY NOTCHED WALL 6) COMPLETE PLUMBING TO WATER HEATER NEW LOCATION 7) FIRE STOP OVER KNOTCHED TOP PLATE KITCHEN WALL 8) PROVIDE WATER POND METALLIC PLUMBING |
| 09/15/2009 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 08/31/2010 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
| 08/31/2010 | ELECTRIC - FINAL | RRICH | Approved | IVRS - Inspection :* |