Permit: T09CM02193
Permit Details
Apply Date:
08/17/2009
Applicant:
N/A
Description:
SOLAR WATER HEATER RES
Contractors:
- CUSTOM SOLAR AND LEISURE L L C
Permit Reviews
Permit Number - T09CM02193
Permit Status: Expired
Permit Description: SOLAR WATER HEATER RES
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/17/2009 | RESIDENTIAL BLDG/ZONING/ENGINE/NPPO | 08/17/2009 | ACTIVE |
Outstanding Activity Conditions
Permit Number - T09CM02193
Permit Status: Expired
Permit Description: SOLAR WATER HEATER RES
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/17/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T09CM02193
Permite Description: SOLAR WATER HEATER RES
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/21/2009 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* 1) EXTEND THE GAS WATER HEATER VENT TO 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' WITH DBL WALL VENT PIPING 2) PRESSURE RELIEF AT PANEL NEED TO TERMINATE CLOSE TO ROOF TO PREVENT SCALDING 3) PROVIDE SUPPORT AND SECURE EXPANSION TANK ? PLASTIC STRAP DOES NOT MEET MINIMUM REQUIREMENT |
Completed Inspections
Permit Status: Expired
Permit Number: T09CM02193
Permit Description: SOLAR WATER HEATER RES
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/21/2009 | BUILDING - FINAL | RRICH | Approved | IVRS - Inspection :* |