Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T09CM02110
Permit Details
Apply Date:
08/06/2009
Applicant:
N/A
Description:
INST 2 - 5 TON GAS PACK UNIT (T09DV04329)
Contractors:
- AIR EXCELLENCE
Permit Reviews
Permit Number - T09CM02110
Permit Status: Final
Permit Description: INST 2 - 5 TON GAS PACK UNIT (T09DV04329)
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/06/2009 | OTHER | 08/07/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM02110
Permit Status: Final
Permit Description: INST 2 - 5 TON GAS PACK UNIT (T09DV04329)
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/06/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T09CM02110
Permit Description: INST 2 - 5 TON GAS PACK UNIT (T09DV04329)
Total Completed Inspections - 5
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/27/2009 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) SUPPORT THE GAS LINE ON ROOF 2) USE PURPLE PRIMER ON ALL PVC FITTINGS PRIOR TO GLUE 3) TERMINATE TO AN APPROVE LOCATION 4) PROVIDE A FRESS AIR INTAKE 5) PAINT EXPOSED PVC WITH LATEX PAINT 6) PROVIDE THE REQUIRED GFI SERVICE RECEPTACLE ON ROOF |
10/27/2009 | PLUMBING - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
10/27/2009 | PLUMBING - GAS PRESS TEST FNL | JMILITEL | Approved | |
10/27/2009 | PLUMBING - GAS PRESSURE TEST | JMILITEL | Approved | |
10/21/2010 | PERMIT FINALED | BGRANT | Approved |