Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Apply Date:
07/24/2009
Applicant:
PEPPER VINER DEVELOPMENT COMPANY *C
Description:
NEW SFR TD# PEPP200008 T08-M0035
Contractors:
  • PEPPER VINER DEVELOPMENT COMPANY *C

Permit Reviews

Permit Number - T09CM01982
Permit Status: Final
Permit Description: NEW SFR TD# PEPP200008 T08-M0035
Start Date Submittal Complete Date Status  
07/24/2009 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 07/27/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM01982
Permit Status: Final
Permit Description: NEW SFR TD# PEPP200008 T08-M0035
Total Outstanding Activity Conditions - 1
Date Name
07/24/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T09CM01982
Permit Description: NEW SFR TD# PEPP200008 T08-M0035
Total Completed Inspections - 30
Date Description Inspector Results Comments
08/13/2009 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection :*
1) PLUMBED FOR 2 BATHROOMS ONLY
08/13/2009 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection :*
08/13/2009 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection :*
08/20/2009 ELECTRIC - UNDERGROUND RFREIDIN Approved IVRS - Inspection :*
08/20/2009 ELECTRIC - UFER RFREIDIN Approved IVRS - Inspection :*
08/20/2009 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection :*
08/20/2009 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection :*
09/16/2009 ROOF NAILING RFREIDIN Approved IVRS - Inspection :*
AT NEXT INSPECTION CHECK DOUBLE HANGERS IN GARAGE, NOT LABELED ON PLANS
10/02/2009 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved
10/02/2009 ELECTRIC - CABLE DROP RFREIDIN Approved
10/05/2009 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER R. FREIDINGER
10/14/2009 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved IVRS - Inspection :*
10/14/2009 FRAMING RFREIDIN Approved IVRS - Inspection :*
10/14/2009 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
10/14/2009 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
10/14/2009 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
10/14/2009 U VALUE FOR WINDOW RFREIDIN Approved IVRS - Inspection :*
10/14/2009 STUCCO MESH RFREIDIN Approved IVRS - Inspection :*
10/14/2009 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection :*
10/26/2009 SHEET ROCK NAILING DQUINN Approved IVRS - Inspection :*
02/16/2010 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection :*
02/16/2010 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection :*
02/16/2010 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection :*
02/19/2010 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection :*
02/23/2010 PERMIT FINALED BFLORES Approved
02/23/2010 MECHANICAL - PROGRESS RFREIDIN Approved
02/23/2010 PLUMBING - PROGRESS RFREIDIN Approved
02/23/2010 ELECTRIC - OUTDOOR LIGHTING RFREIDIN Approved
02/23/2010 ELECTRIC - PROGRESS RFREIDIN Approved
02/23/2010 BUILDING - PROGRESS RFREIDIN Approved

Documents

File Name Document Type  
C OF O_02-23-2010.TIF CERT OF OCC VIEW
None DOCUMENTS VIEW
SITE PLAN_07-27-2009.TIF CONSTRPLANS VIEW