Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY COMPLIANCE
Address:
821 W BAFFIN DR
Address NEW:
821 W BAFFIN DR
Apply Date:
06/09/2009
Applicant:
N/A
Description:
CODE COMPLIANCE: ENCLOSE CARPORT TO DEN & ADDT OF STORAGE & WORKSHOP & DEMOLITION OF C/P & PORCH TO PROPERTY LINE OF HOUSE

Permit Reviews

Permit Number - T09CM01471
Permit Status: Final
Permit Description: CODE COMPLIANCE: ENCLOSE CARPORT TO DEN & ADDT OF STORAGE & WORKSHOP & DEMOLITION OF C/P & PORCH TO PROPERTY LINE OF HOUSE
Start Date Submittal Complete Date Status  
06/09/2009 RESIDENTIAL BLDG/ZONING-WALKTHRU 09/18/2009 COMPLETED Review Details
09/18/2009 RESIDENTIAL BLDG/ZONING-WALKTHRU 09/18/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM01471
Permit Status: Final
Permit Description: CODE COMPLIANCE: ENCLOSE CARPORT TO DEN & ADDT OF STORAGE & WORKSHOP & DEMOLITION OF C/P & PORCH TO PROPERTY LINE OF HOUSE
Total Outstanding Activity Conditions - 1
Date Name
06/09/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T09CM01471
Permit Description: CODE COMPLIANCE: ENCLOSE CARPORT TO DEN & ADDT OF STORAGE & WORKSHOP & DEMOLITION OF C/P & PORCH TO PROPERTY LINE OF HOUSE
Total Completed Inspections - 3
Date Description Inspector Results Comments
12/16/2009 BUILDING - PROGRESS RCAMACHO Approved IVRS - Inspection :*
OFFICE/DEN:
1) PROVIDE LETTERHEAD LICENSED ELECTRICIAN THAT ALL ELECTRICAL WORK TO CODE OR EXPOSE
2) MISSING OUTLET PER CODE WEST WALL
3) EXPOSED ROMEX IN CLOSETS
4) EXPOSE FOOTERS AND BOTTOM PLATES
5) CARPORT DEMOLISHED
6) SECURE LATHE 6" ON CENTER EVERY STUD, TOP AND BOTTOM PLATES. FHA WEEP REQUIRED SEAL PROTECTION
7) NO INSPECTIONS TO WORK SHOP STORAGE AT THIS TIME PER OWNER
8) EXPOSED DUCT CLOSET
06/03/2010 PERMIT FINALED JWEATHER Approved
06/03/2010 BUILDING - FINAL RCAMACHO Approved APPROVED PER LETTER PROVIDED BY FIELD SUPERVISOR MIKE TESTA OF DELTA POWER CORP.

Documents

File Name Document Type  
001_PLAN.TIF CONSTRPLANS VIEW
002_PLAN.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW