Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T09CM00689
Permit Details
Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
345 S VIA GOLONDRINA
Address NEW:
345 S VIA GOLONDRINA
Apply Date:
03/27/2009
Applicant:
N/A
Description:
REMODEL AND ADD TO EXISTING HOUSE R1: CHANGE TO FIRE SPRINKLER PLANS
Architects:
- PAULUS, KEVIN M
Permit Reviews
Permit Number - T09CM00689
Permit Status: Final
Permit Description: REMODEL AND ADD TO EXISTING HOUSE
R1: CHANGE TO FIRE SPRINKLER PLANS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/27/2009 | RESIDENTIAL BLDG/ZONING/ENGINE/WWM | 03/27/2009 | COMPLETED |
| 03/27/2009 | RESIDENTIAL BLDG/WWM | 06/04/2009 | COMPLETED |
| 06/04/2009 | REVISION - - 1ST | 06/04/2009 | COMPLETED |
| 12/11/2009 | REVISION - - 2ND | 12/11/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM00689
Permit Status: Final
Permit Description: REMODEL AND ADD TO EXISTING HOUSE
R1: CHANGE TO FIRE SPRINKLER PLANS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/27/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T09CM00689
Permit Description: REMODEL AND ADD TO EXISTING HOUSE
R1: CHANGE TO FIRE SPRINKLER PLANS
Total Completed Inspections - 20
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/02/2009 | BUILDING PRE-SLAB | WNORTH | Approved | IVRS - Inspection :* |
| 06/02/2009 | EXCAVATION/LAYOUT REBAR & ZON | WNORTH | Approved | IVRS - Inspection :* |
| 06/05/2009 | PLUMBING - SEWER HCS CONNECT | WNORTH | Approved | IVRS - Inspection :* CONNECTED TO EXISTING YARD LINE |
| 06/05/2009 | PLUMBING - ROUGH, SOIL | WNORTH | Approved | IVRS - Inspection :* |
| 07/24/2009 | EXT METAL CLIPS/EXT SHEATHING | DQUINN | Approved | PARAPET CLIPS OK TO COVER |
| 07/24/2009 | ROOF NAILING | DQUINN | Approved | IVRS - Inspection :* |
| 10/02/2009 | PLUMBING - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* 1) N.E. TUB AND FAUCETS NOT READY 2) MASTER LACKING SHOWER VALVES 3) GAS INTO MECH ROOMS AND FIREPLACE BUT NOT DISTRIBUTED 4) ALL OTHER PLUMBING OK TO BURY |
| 11/19/2009 | U VALUE FOR WINDOW | EDURAZO | Approved | IVRS - Inspection :* |
| 11/24/2009 | FRAMING | DQUINN | Approved | IVRS - Inspection :* GARAGE DOORS OK TO ROCK |
| 12/09/2009 | MECHANICAL - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* 1) GARAGE OK TO INSULATE AND ROCK |
| 12/21/2009 | SHEET ROCK NAILING | DQUINN | Approved | IVRS - Inspection :* 1) GARAGE ROCK OK |
| 01/12/2010 | PLUMBING - GAS PRESSURE TEST | DQUINN | Approved | |
| 01/12/2010 | ELECTRIC - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 01/22/2010 | ELECTRIC - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 06/08/2010 | MECHANICAL - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 12/13/2010 | ELECTRIC - UFER | WLAHR | Approved | IVRS - Inspection :* |
| 12/14/2010 | OUTDOOR LIGHTING FINAL | DQUINN | Approved | IVRS - Inspection :* 1) CAP OFF OBSOLITE FIXTURE BOXES |
| 12/14/2010 | PLUMBING - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 12/14/2010 | BUILDING - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 12/16/2010 | PERMIT FINALED | JWEATHER | Approved |