Permit Details

Status:
Expired
Type:
SINGLE FAMILY NEW
Apply Date:
03/10/2009
Applicant:
RICHMOND AMERICAN HOMES *C
Description:
SFR:RICH001797 T08-M0049
Contractors:
  • RICHMOND AMERICAN HOMES *C

Permit Reviews

Permit Number - T09CM00546
Permit Status: Expired
Permit Description: SFR:RICH001797 T08-M0049
Start Date Submittal Complete Date Status  
03/10/2009 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 03/12/2009 ACTIVE Review Details

Outstanding Activity Conditions

Permit Number - T09CM00546
Permit Status: Expired
Permit Description: SFR:RICH001797 T08-M0049
Total Outstanding Activity Conditions - 1
Date Name
03/10/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T09CM00546
Permite Description: SFR:RICH001797 T08-M0049
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
PLUMBING - PRE SLAB N/A Not Inspected
PLUMBING - GAS PRESS TEST FNL N/A Not Inspected
04/20/2009 FRAMING N/A Partial Approval IVRS - Inspection :*
HANGER ON FLOOR TRUSS FTOG
INSIDE FLANGE HANGER - USED, NOT ON PLAN CARRIES 2ND FLR. FRONT WALL

HVC 412

Completed Inspections

Permit Status: Expired
Permit Number: T09CM00546
Permit Description: SFR:RICH001797 T08-M0049
Total Completed Inspections - 23
Date Description Inspector Results Comments
03/20/2009 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection :*
03/20/2009 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection :*
03/20/2009 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection :*
03/25/2009 ELECTRIC - UNDERGROUND RFREIDIN Approved IVRS - Inspection :*
03/25/2009 ELECTRIC - UFER RFREIDIN Approved IVRS - Inspection :*
03/25/2009 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection :*
03/25/2009 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection :*
04/07/2009 ROOF NAILING WNORTH Approved IVRS - Inspection :*
04/07/2009 EXT METAL CLIPS/EXT SHEATHING WNORTH Approved IVRS - Inspection :*
04/20/2009 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
04/20/2009 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved IVRS - Inspection :*
04/20/2009 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
04/20/2009 U VALUE FOR WINDOW RFREIDIN Approved IVRS - Inspection :*
04/20/2009 STUCCO MESH RFREIDIN Approved IVRS - Inspection :*
04/21/2009 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
05/01/2009 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection :*
05/06/2009 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved IVRS - Inspection :*
05/06/2009 ELECTRIC - CABLE DROP RFREIDIN Approved IVRS - Inspection :*
05/07/2009 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER R. FREIDINGER
06/05/2009 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection :*
06/05/2009 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection :*
06/05/2009 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection :*
06/05/2009 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW