Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
2020 N NORTON AV
Address NEW:
2020 N NORTON AV
Apply Date:
03/06/2009
Applicant:
N/A
Description:
ADDITION: BEDROOM AND BATHROOM
Contractors:
  • TALAVERA HOMES INC ,

Outstanding Activity Conditions

Permit Number - T09CM00502
Permit Status: Final
Permit Description: ADDITION: BEDROOM AND BATHROOM
Total Outstanding Activity Conditions - 1
Date Name
03/06/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T09CM00502
Permit Description: ADDITION: BEDROOM AND BATHROOM
Total Completed Inspections - 18
Date Description Inspector Results Comments
04/01/2009 PLUMBING - SEWER HCS CONNECT DQUINN Approved IVRS - Inspection :*
1) HCS IS NEW EAST BATH TYING INTO EXISTING MAIN DRAIN ON NORTH SIDE
04/01/2009 PLUMBING - ROUGH, SOIL DQUINN Approved IVRS - Inspection :*
04/03/2009 BUILDING PRE-SLAB CRUIZ Approved IVRS - Inspection :*
04/03/2009 EXCAVATION/LAYOUT REBAR & ZON CRUIZ Approved IVRS - Inspection :*
05/07/2009 ELECTRIC - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :*
05/07/2009 ROOF NAILING RCAMACHO Approved IVRS - Inspection :*
05/07/2009 EXT METAL CLIPS/EXT SHEATHING RCAMACHO Approved IVRS - Inspection :*
06/04/2009 FRAMING WNORTH Approved IVRS - Inspection :*
06/04/2009 MECHANICAL - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
06/04/2009 PLUMBING - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
06/18/2009 SHEET ROCK NAILING DQUINN Approved IVRS - Inspection :*
08/31/2009 BUILDING - FINAL RCAMACHO Approved IVRS - Inspection :*
1) LABEL CIRCUIT
2) INSTALL FAN
3) STOOP REQUIRED SLIDING DOOR
4) RAISED LETTER ADDRESS ON PANEL
08/31/2009 MECHANICAL - FINAL RCAMACHO Approved IVRS - Inspection :*
08/31/2009 PLUMBING - FINAL RCAMACHO Approved IVRS - Inspection :*
08/31/2009 ELECTRIC - FINAL RCAMACHO Approved IVRS - Inspection :*
08/31/2009 ELECTRIC - SERVICE UPGRADE RCAMACHO Approved IVRS - Inspection :*
08/31/2009 U VALUE FOR WINDOW RCAMACHO Approved IVRS - Inspection :*
01/26/2010 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
001_PLOT.TIF CONSTRPLANS VIEW
002_FLOOR.TIF CONSTRPLANS VIEW
003_FOUNDATION.TIF CONSTRPLANS VIEW
004_ELEVATION.TIF CONSTRPLANS VIEW
005_PLUMBING.TIF CONSTRPLANS VIEW
006_MECHANICAL.TIF CONSTRPLANS VIEW
007_ELECTRICAL.TIF CONSTRPLANS VIEW
008_ROOF.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW