Permit: T09CM00445
Permit Details
Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
840 W PARIS PROMENADE
Address NEW:
840 W PARIS PROMENADE
Apply Date:
02/27/2009
Applicant:
N/A
Description:
ADDITION: PORCH TO FAMILY ROOM:UPGRADE 200AMP
Permit Reviews
Permit Number - T09CM00445
Permit Status: Final
Permit Description: ADDITION: PORCH TO FAMILY ROOM:UPGRADE 200AMP
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/27/2009 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 03/13/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM00445
Permit Status: Final
Permit Description: ADDITION: PORCH TO FAMILY ROOM:UPGRADE 200AMP
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/27/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T09CM00445
Permit Description: ADDITION: PORCH TO FAMILY ROOM:UPGRADE 200AMP
Total Completed Inspections - 13
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/23/2009 | EXCAVATION/LAYOUT REBAR & ZON | RCAMACHO | Approved | IVRS - Inspection :* 1) VIRIFICATION OF FOOTERS, ALL READY POURED EXISTING 12" DEPTH |
| 03/27/2009 | ROOF NAILING | CRUIZ | Approved | IVRS - Inspection :* |
| 03/27/2009 | EXT METAL CLIPS/EXT SHEATHING | CRUIZ | Approved | IVRS - Inspection :* |
| 04/16/2009 | ELECTRIC - SERVICE UPGRADE | CRUIZ | Approved | IVRS - Inspection :* |
| 04/16/2009 | STUCCO MESH | CRUIZ | Approved | IVRS - Inspection :* |
| 04/16/2009 | FRAMING | CRUIZ | Approved | IVRS - Inspection :* |
| 04/16/2009 | MECHANICAL - INTERMEDIATE | CRUIZ | Approved | IVRS - Inspection :* |
| 04/16/2009 | ELECTRIC - INTERMEDIATE | CRUIZ | Approved | IVRS - Inspection :* |
| 04/17/2009 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED PER C. RUIZ |
| 11/10/2009 | ELECTRIC - FINAL | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE 3' X 3' STOOP EXIT DOOR 2) COMPLETE SHEETROCK LAUNDRY ROOM 3) TERMINATE CONDENSATE ROOFS EDGE 4) COMBUSTION RELIEF WATER HEATER ROOM 5) EXTEND TPR LINE TO EXTERIOR 6"-24" FROM GROUND 6) SHEETROCK WATER HEATER ROOM |
| 11/10/2009 | MECHANICAL - FINAL | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 11/10/2009 | BUILDING - FINAL | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 10/21/2010 | SHEET ROCK NAILING | RCAMACHO | Approved | IVRS - Inspection :* |