Permit: T09CM00319
Permit Details
Apply Date:
02/11/2009
Applicant:
N/A
Description:
MODULAR OFFICE BUILDING
Architects:
- BONESTEEL, SHARON ANN
Contractors:
- ELECTRIC CHUCK *C
- IN AND OUT PLUMBING SEWER AND DRAIN SERVICE L L
Permit Reviews
Permit Number - T09CM00319
Permit Status: L of c
Permit Description: MODULAR OFFICE BUILDING
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/11/2009 | MODULAR BUILDINGS | 03/02/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM00319
Permit Status: L of c
Permit Description: MODULAR OFFICE BUILDING
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
02/11/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: L of c
Permit Number: T09CM00319
Permit Description: MODULAR OFFICE BUILDING
Total Completed Inspections - 14
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/17/2009 | ELECTRIC - CABLE DROP | RMORENO | Approved | IVRS - Inspection :* |
03/18/2009 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED FOR R. MORENO |
11/19/2009 | BUILDING - FINAL | MHENSON | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) ACCESSABILITY DOES NOT COMPLY-RAMPS AND BATHROOM NEEDS VERTICAL GRAB BAR-REFER TO ANSI A117.1 SEC 405 RAMPS 2) STATE AND FIRE APPROVED 3) VAN ACCESSIBLE PARKING DOES NOT COMPLY ANSI A117.1 SEC 501 4) NEED ENGINEERING FINAL 5) 3/4" COPPER WITH BACKFLOW FOR H20 SUPPLY |
11/19/2009 | FIRE - HYDRANTS | LTHOMAS | Approved | |
11/19/2009 | FIRE - FINAL | LTHOMAS | Approved | |
11/19/2009 | BUILDING - PROGRESS | MHENSON | Approved | IVRS - Inspection :* |
11/19/2009 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
11/19/2009 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* |
11/19/2009 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection :* |
11/19/2009 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection :* |
11/19/2009 | NPPO - FINAL | JLINVILLE | Approved | N/A |
11/19/2009 | LANDSCAPE - FINAL | JLINVILLE | Approved | N/A |
11/19/2009 | ENGINEERING - FINAL | JFEMLING | Approved | Complete the following prior to C of O. 1) revise site plan and submit to PDSD for review and apporval. 2) install bike parking per approved plan 3) ADA ramp to office does not meet ANSI std. 4) Provide bumper blocks for parking per approved plan or remove from plan. 5) show storage units on revised site plan or remove from site. 6) call for re-inspection. |
02/04/2019 | RIGHT OF WAY - FINAL | DROBERTS | Approved |