Permit Details

Status:
Expired
Type:
SINGLE FAMILY COMPLIANCE
Address:
6707 S LUNDY AV
Address NEW:
6707 S LUNDY AV
Apply Date:
02/02/2009
Applicant:
N/A
Description:
ENCLOSURE:CARPORT TO FAMILY ROOM & ELECTRIC WORK -CODE COMPLIANCE

Permit Reviews

Permit Number - T09CM00254
Permit Status: Expired
Permit Description: ENCLOSURE:CARPORT TO FAMILY ROOM & ELECTRIC WORK -CODE COMPLIANCE
Start Date Submittal Complete Date Status  
02/02/2009 RESIDENTIAL BLDG/ZONING/ENGINE/NPPO 02/02/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM00254
Permit Status: Expired
Permit Description: ENCLOSURE:CARPORT TO FAMILY ROOM & ELECTRIC WORK -CODE COMPLIANCE
Total Outstanding Activity Conditions - 1
Date Name
02/02/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T09CM00254
Permite Description: ENCLOSURE:CARPORT TO FAMILY ROOM & ELECTRIC WORK -CODE COMPLIANCE
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
02/04/2009 BUILDING - PROGRESS N/A Not ready for Inspection IVRS - Inspection :*
1. NEED OUTLETS PER CODE IN CARPORT ENCLOSURE (6 & 12)
2. KITCHEN COUNTER OUTLETS TO BE GFI
3. NEED GFI PROTECTION & OUTLETS IN BATHROOM
4. REMOVE HOT-WIRED CIRCUITS IN MAIN PANEL
5. PROTECT ALL ROMEX BELOW 8' - CONDUIT OR SHEETROCK
6. REMOVE DOUBLE TAPPED WIRE IN CLOSET SUB-PANEL
7. ALL BEDROOM WINDOW BARS HAVE TO BE OPERABLE OR REMOVED
8. NEED SMOKE DETECTORS IN EACH BED AND HALLWAY

Completed Inspections

Permit Status: Expired
Permit Number: T09CM00254
Permit Description: ENCLOSURE:CARPORT TO FAMILY ROOM & ELECTRIC WORK -CODE COMPLIANCE
Total Completed Inspections - 1
Date Description Inspector Results Comments
04/29/2009 BUILDING - FINAL DQUINN Approved IVRS - Inspection :*

Documents

File Name Document Type  
None CONSTRPLANS VIEW
None DOCUMENTS VIEW