Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Address NEW:
7857 E TREETOP RD
Apply Date:
01/22/2009
Applicant:
N/A
Description:
SFR: LENN000052 T08-0116
Contractors:
  • LENNAR ARIZONA CONSTRUCTION *P *C

Permit Reviews

Permit Number - T09CM00173
Permit Status: C of o
Permit Description: SFR: LENN000052 T08-0116
Start Date Submittal Complete Date Status  
01/22/2009 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 01/22/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM00173
Permit Status: C of o
Permit Description: SFR: LENN000052 T08-0116
Total Outstanding Activity Conditions - 1
Date Name
01/22/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T09CM00173
Permit Description: SFR: LENN000052 T08-0116
Total Completed Inspections - 27
Date Description Inspector Results Comments
02/10/2009 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection :*
02/10/2009 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection :*
02/10/2009 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection :*
02/19/2009 EXCAVATION/LAYOUT REBAR & ZON WLAHR Approved IVRS - Inspection :*
1) OK PER PREVIOUS INSPECTION
02/19/2009 BUILDING PRE-SLAB WLAHR Approved IVRS - Inspection :*
02/19/2009 STEM WALL/RETAINING WALL WLAHR Approved IVRS - Inspection :*
02/19/2009 ELECTRIC - UNDERGROUND WLAHR Approved IVRS - Inspection :*
02/27/2009 ROOF NAILING RFREIDIN Approved IVRS - Inspection :*
03/05/2009 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved IVRS - Inspection :*
03/05/2009 ELECTRIC - CABLE DROP RFREIDIN Approved IVRS - Inspection :*
03/06/2009 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER R. FREIDINGER
03/12/2009 MECHANICAL - INTERMEDIATE WLAHR Approved IVRS - Inspection :*
03/12/2009 PLUMBING - GAS PRESSURE TEST WLAHR Approved IVRS - Inspection :*
03/12/2009 ELECTRIC - OUTDOOR LIGHTING WLAHR Approved IVRS - Inspection :*
03/12/2009 U VALUE FOR WINDOW WLAHR Approved IVRS - Inspection :*
03/12/2009 STUCCO MESH WLAHR Approved IVRS - Inspection :*
03/13/2009 FRAMING RFREIDIN Approved IVRS - Inspection :*
03/13/2009 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
03/13/2009 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
03/13/2009 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection :*
03/23/2009 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection :*
1) NOTE: NAIL DRYWALL REAR PORCH TO BRACES CEILING 5'-4" ON CENTER
05/06/2009 ELECTRIC - UFER RFREIDIN Approved
05/06/2009 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection :*
05/06/2009 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection :*
05/06/2009 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection :*
05/06/2009 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection :*
05/07/2009 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
C OF O_05-07-2009.TIF CERT OF OCC VIEW
None DOCUMENTS VIEW
SITE PLAN_01-22-2009.TIF CONSTRPLANS VIEW