Permit: T08PL01090
Permit Details
Apply Date:
07/21/2008
Applicant:
ABACUS PLUMBING CO;*C,*P
Description:
REPLACE: GASLINE (APA)
Contractors:
- ABACUS PLUMBING CO;*C,*P
Outstanding Activity Conditions
Permit Number - T08PL01090
Permit Status: Expired
Permit Description: REPLACE: GASLINE (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/21/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T08PL01090
Permite Description: REPLACE: GASLINE (APA)
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/30/2008 | PLUMBING - INTERMEDIATE | N/A | Partial Approval | IVRS - Inspection :* |
| 07/30/2008 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* THIS IS A WATER HEATER ONLY INSPECTION. GAS IS ON. CORRECT VENT CONNECTOR, MAKE UP JOINTS PROPERLY AND SECURE W/SCREWS AT EACH JOINT. SEDIMENT TRAP REQUIRED AND PETITION OF APPEAL FOR T&P RELIEF INTO PAN. ALSO, AIR GAP REQUIRED AND EXTERIOR RELIEF VALVE TERMINATION IS W/OUT THREADS. |