Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
4702 E EASTLAND ST
Apply Date:
02/19/2008
Applicant:
JOE CLARK
Description:
REPL GAS LINE (1 1/4")

Permit Reviews

Permit Number - T08PL00323
Permit Status: Expired
Permit Description: REPL GAS LINE (1 1/4")
Start Date Submittal Complete Date Status  
02/19/2008 PLUMBING 02/19/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08PL00323
Permit Status: Expired
Permit Description: REPL GAS LINE (1 1/4")
Total Outstanding Activity Conditions - 1
Date Name
02/19/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T08PL00323
Permite Description: REPL GAS LINE (1 1/4")
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
03/04/2008 PLUMBING - GAS PRESSURE TEST N/A Partial Approval IVRS - Inspection :*
- 1/2" GAS PIPE TO FURNACE NOT ADEQUATE FOR
80,000 BTU PROVIDE MIN. 3/4"
- RETEST SYSTEM
- 10 PSI TEST IS OK
- OK TO BACKFILL TRENCH
- INSTALL WATER HEATER & PROVIDE PERMIT FOR WATER HEATER INSTALLATION AND NEW A/C UNIT ON ROOF.

Documents

File Name Document Type  
None DOCUMENTS VIEW