Permit: T08PL00181
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
7025 E CALLE PEGASO
Address NEW:
7025 E CALLE PEGASO
Apply Date:
01/29/2008
Applicant:
FORREST BOL
Description:
REPLACE:WATER LINE:GAS LINE
Contractors:
- HILBERT PLUMBING CO , T S
Permit Reviews
Permit Number - T08PL00181
Permit Status: Expired
Permit Description: REPLACE:WATER LINE:GAS LINE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/29/2008 | PLUMBING | 01/29/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08PL00181
Permit Status: Expired
Permit Description: REPLACE:WATER LINE:GAS LINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/29/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T08PL00181
Permite Description: REPLACE:WATER LINE:GAS LINE
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| PLUMBING - YARD WTR LINE/TEST | N/A | Not Inspected | ||
| 02/04/2008 | PLUMBING - GAS PRESSURE TEST | N/A | Partial Approval | IVRS - Inspection :* |
| 02/04/2008 | PLUMBING - FINAL | N/A | Not ready for Inspection | 1) FURNACE VENT TO TERMINATE 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' WITH DBL WALL VENT PIPING AND APPROVED VENT CAP 2) PROVIDE BONDING OF BLDG GAS PIPING 3) COMPLETE YARED WATER PIPING |