Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
7025 E CALLE PEGASO
Apply Date:
01/29/2008
Applicant:
FORREST BOL
Description:
REPLACE:WATER LINE:GAS LINE
Contractors:
  • HILBERT PLUMBING CO , T S

Permit Reviews

Permit Number - T08PL00181
Permit Status: Expired
Permit Description: REPLACE:WATER LINE:GAS LINE
Start Date Submittal Complete Date Status  
01/29/2008 PLUMBING 01/29/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08PL00181
Permit Status: Expired
Permit Description: REPLACE:WATER LINE:GAS LINE
Total Outstanding Activity Conditions - 1
Date Name
01/29/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T08PL00181
Permite Description: REPLACE:WATER LINE:GAS LINE
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
PLUMBING - YARD WTR LINE/TEST N/A Not Inspected
02/04/2008 PLUMBING - GAS PRESSURE TEST N/A Partial Approval IVRS - Inspection :*
02/04/2008 PLUMBING - FINAL N/A Not ready for Inspection 1) FURNACE VENT TO TERMINATE 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' WITH DBL WALL VENT PIPING AND APPROVED VENT CAP
2) PROVIDE BONDING OF BLDG GAS PIPING
3) COMPLETE YARED WATER PIPING

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW