Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
410 W AJO WY
Address NEW:
410 W AJO WY
Apply Date:
01/17/2008
Applicant:
JOE ROMERO
Description:
GAS RECONNECT

Outstanding Activity Conditions

Permit Number - T08PL00109
Permit Status: Expired
Permit Description: GAS RECONNECT
Total Outstanding Activity Conditions - 1
Date Name
01/17/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T08PL00109
Permite Description: GAS RECONNECT
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
02/05/2008 PLUMBING - GAS RECONNECT N/A Partial Approval IVRS - Inspection :*
PSI TEST OK
PROVIDE PERMIT FOR NEW WH
TERMINATE T&P DRAIN 6"-24" ABV GRADE
CORRECT B VENT, UPSIDE DOWN AND TOUCHING WOOD
INSTALL BRACKET AT EVE
AGA VALVE SEDIMENT TRAP. SECURE PIPING AT WH

Documents

File Name Document Type  
None DOCUMENTS VIEW