Permit: T08PL00026
Permit Details
Status:
Expired
Type:
COMMERCIAL OTHER
Address:
6424 E TANQUE VERDE RD
Address NEW:
6424 E TANQUE VERDE RD
Apply Date:
01/04/2008
Applicant:
ROGER HARRISON
Description:
INCREASE GAS PRESSURE
Contractors:
- ROGER'S PLUMBING COMPANY *T
Permit Reviews
Permit Number - T08PL00026
Permit Status: Expired
Permit Description: INCREASE GAS PRESSURE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/04/2008 | PLUMBING | 01/04/2008 | COMPLETED |
| 01/23/2008 | PLUMBING | 01/23/2008 | ACTIVE |
Outstanding Activity Conditions
Permit Number - T08PL00026
Permit Status: Expired
Permit Description: INCREASE GAS PRESSURE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/04/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T08PL00026
Permite Description: INCREASE GAS PRESSURE
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| PLUMBING - GAS PRESSURE TEST | N/A | Not Inspected | ||
| 01/10/2008 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* SPECIFY SUITE # ON ACTIVITY AND IDENTIFY GAS METER SERVING GENERATOR. ALSO, POST ADDRESS AND SUITE NUMBER ON BUILDING. - PROVIDE AN ISOMETRIC DRAWING WITH THE FOLLOWING INFORMATION. - BTU DEMAND OF ALL APPLIANCES OR EQUIPMENT SERVED BY THIS SYSTEM - TOTAL DEVELOPED LENGTH OF PIPING - SIZE OF PIPING AND GAS PRESSURE SUPPLIED TO EQUIPMENT, INCLUDE ANY REGULATING DEVICES - PROVIDE AN AIR PRESSURE TEST ON PIPING SYSTEM |