Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
COMMERCIAL OTHER
Address:
341 N HOFF AV
Apply Date:
04/10/2008
Applicant:
KERI LAZARUS SILVYN
Description:
C OF O

Outstanding Inspections

Permit Status: Expired
Permit Number: T08OT00839
Permite Description: C OF O
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
FIRE - FINAL N/A Not Inspected
SIGN - FINAL N/A Not Inspected
04/30/2008 CERTIFICATE OF OCCUPANCY N/A Denied 1. SUPPORT GAS LINES
2. FLOOR REPAIR REQUIRED UNDER WATER HEATER
3. VENTILATION REQUIRED FOR RESTROOM
4. REPAIR ELECTRIC OUTLETS (COVERS, DO NOT USE 3 PRONG RECEPTACLES IN TWO WIRE SYSTEM)
a. ELECTRICAL DISCONNECT & FEEDERS TO BE REPAIRED PER NEC REQUIREMENTS
5. PROVIDE ACCESSIBLE ROUTE INTO AND THROUGH SPACE ONTO PATIO AREA
6. PROVIDE ANALYSIS BY REGISTERED PROFESSIONAL FOR ADOBE COLUMN BETWEEN UNITS 341 & 343 @ REAR
7. EXIT OFF PATIO REQUIRED PER CHAPTER 10 OF IBC

Documents

File Name Document Type  
None DOCUMENTS VIEW