Permit: T08EL02195
Permit Details
Apply Date:
11/24/2008
Applicant:
ROBER GRANT
Description:
RECONNECT:ELECTRIC RESIDENCE
Outstanding Activity Conditions
Permit Number - T08EL02195
Permit Status: Expired
Permit Description: RECONNECT:ELECTRIC RESIDENCE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/24/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T08EL02195
Permite Description: RECONNECT:ELECTRIC RESIDENCE
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/25/2008 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HAZARDOUS ELECTRICAL FRONT LIGHT FIXTURE REMOVE EXTENSION CORD SEAL BOX 2) PROVIDE PROOF OF PERMIT CARPORT ENCLOSURE AND FRONT PORCH 3) HAZARDOUS ELECTRICAL CIRCUIT DLB LUGGED MAIN PANEL REMOVE ADDED CIRCUIT 220 TO LAUNDRY 4) BOND WATER AND GAS LINES SEAL KNOCKOUTS IN DEAD FRONT 5) REMOVE REAR EXTERIOR EXPOSE LAMP CORD WIRING 6) PROVIDE COMBUSTION RELIEF WATER HEATER EXTEND RELIEF LINE TO EXTERIOR 7) GFCI PROTECT KITCHEN COUNTER OUTLETS AND BATH 8) ELECTRICAL AT STOVE NOT TO CODE 9) REMOVE LAMP CORD FIXTURE LIVING ROOM AND BEDROOMS 10) SMOKE ALARMS BEDROOMS AND HALLWAY 11) HAZARDOUS WIRING COOLER SWITCHES |
Completed Inspections
Permit Status: Expired
Permit Number: T08EL02195
Permit Description: RECONNECT:ELECTRIC RESIDENCE
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/25/2008 | ELECTRIC - RECONNECT | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 02/26/2009 | TEP CLEARANCE - PM | BFLORES | Approved | RECN PER R.CAMACHO |