Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
4729 S LANTANA CI
Apply Date:
06/19/2008
Applicant:
JOSEPH PALAZZOLO
Description:
RECONNECT:ELETRIC:SFR

Outstanding Activity Conditions

Permit Number - T08EL01129
Permit Status: Expired
Permit Description: RECONNECT:ELETRIC:SFR
Total Outstanding Activity Conditions - 1
Date Name
06/19/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T08EL01129
Permite Description: RECONNECT:ELETRIC:SFR
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
06/23/2008 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TO CLEAN UP WIRING GARAGE
2) 30 AMP BREAKER IN PANEL #12 WIRE
3) PROTECT ALL WIRING IN GARAGE TO 8'-0" HT
4) ALL RECEPTS IN GARAGE TO BE GFCI PROTECTED
5) PLUG HOLE IN SERVICE PANEL
6) ISOLATE NEUTRALS AND GROUNDS IN SUB PANEL

Completed Inspections

Permit Status: Expired
Permit Number: T08EL01129
Permit Description: RECONNECT:ELETRIC:SFR
Total Completed Inspections - 2
Date Description Inspector Results Comments
06/23/2008 ELECTRIC - RECONNECT RFREIDIN Approved IVRS - Inspection :*
06/24/2008 TEP CLEARANCE - AM JWEATHER Approved RECN CLEARED PER R. FREIDINGER