Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T08EL00610
Permit Details
Apply Date:
04/15/2008
Applicant:
ANNE POULIN
Description:
ELECTRIC RECONNECT
Outstanding Activity Conditions
Permit Number - T08EL00610
Permit Status: Closed
Permit Description: ELECTRIC RECONNECT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/15/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T08EL00610
Permite Description: ELECTRIC RECONNECT
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/16/2008 | ELECTRIC - RECONNECT | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 04/16/2008 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL SMOKE DETECTORS IN ALL BEDROOMS AND HALLWAY 2) PROTECT WIRES AT WATER HEATER 3) THERE ARE NUMEROUS VIOLATIONS AT THE MAIN DISCONNECT INCLUDING DBL LUGGED WIRES AND OVER FUSED WIRES AND UN-PROTECTED WIRES. A NEW PANEL WILL BE REQUIRED 4) SEVERAL INTERIOR CIRCUITS OVERF USED 6) WERE PERMITS AND INSPECTIONS OBTAINED FOR THE ADDITIONS ? |