Permit: T08EL00176
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
2520 E CAMERON VISTA
Address NEW:
2520 E CAMERON VISTA
Apply Date:
01/30/2008
Applicant:
RHONDA SANDOVAL
Description:
ELEC RECONNECT
Outstanding Activity Conditions
Permit Number - T08EL00176
Permit Status: Expired
Permit Description: ELEC RECONNECT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/30/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T08EL00176
Permite Description: ELEC RECONNECT
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/13/2008 | ELECTRIC - RECONNECT | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 90 DEGREE FITTING AT EMT SHALL BE WATER TIGHT 2) PROTECT FLAT ROMEX FROM WEATHER 3) EXTERIOR OUTLET AT TOP S. EAST CORNER SHALL BE GFI. GROUNDED OUTLET NOT ALLOWED IN THIS HOUSE S.W. BEDROOM 4) EXTEND LIGHT FIXTURE BOX IN LIVING ROOM TO CEILING AND SECURE 5) PROVIDE FIXTURE GLOBES TO REAR BEDROOM LIGHTS, KITCHEN AND OUTSIDE LIGHT 6) INSTALL ALL MISSING SWITCH AND OUTLET COVERS |