Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T08CM03848
Permit Details
Apply Date:
12/10/2008
Applicant:
N/A
Description:
SFR PULTSM3503 T08-M0142
Contractors:
- PULTE HOME CORP AZ *C
Permit Reviews
Permit Number - T08CM03848
Permit Status: Expired
Permit Description: SFR PULTSM3503 T08-M0142
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
12/10/2008 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 12/11/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM03848
Permit Status: Expired
Permit Description: SFR PULTSM3503 T08-M0142
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
12/10/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T08CM03848
Permite Description: SFR PULTSM3503 T08-M0142
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/21/2009 | ASSURANCE | N/A | Not ready for Inspection | REINSPECT IN 2WKS. |
Completed Inspections
Permit Status: Expired
Permit Number: T08CM03848
Permit Description: SFR PULTSM3503 T08-M0142
Total Completed Inspections - 25
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/18/2008 | PLUMBING - YARD WTR LINE/TEST | WLAHR | Approved | IVRS - Inspection :* |
12/19/2008 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | IVRS - Inspection :* 1) 3" C/O REQUIRED AT OPT. POWDER ROOM, PLAN CALLS FOR 2" C/O |
12/19/2008 | PLUMBING - SEWER HCS CONNECT | RFREIDIN | Approved | IVRS - Inspection :* |
12/22/2008 | ELECTRIC - UFER | WLAHR | Approved | IVRS - Inspection :* 1) REBAR OK |
12/22/2008 | BUILDING PRE-SLAB | WLAHR | Approved | IVRS - Inspection :* |
12/22/2008 | EXCAVATION/LAYOUT REBAR & ZON | WLAHR | Approved | IVRS - Inspection :* |
01/06/2009 | EXT METAL CLIPS/EXT SHEATHING | WLAHR | Approved | IVRS - Inspection :* |
01/07/2009 | ROOF NAILING | WLAHR | Approved | IVRS - Inspection :* |
01/08/2009 | ELECTRIC - TEMPORARY SERVICE | WLAHR | Approved | IVRS - Inspection :* |
01/08/2009 | ELECTRIC - CABLE DROP | WLAHR | Approved | IVRS - Inspection :* |
01/09/2009 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER W. LAHR |
01/13/2009 | U VALUE FOR WINDOW | WLAHR | Approved | IVRS - Inspection :* |
01/13/2009 | STUCCO MESH | WLAHR | Approved | IVRS - Inspection :* |
01/13/2009 | PLUMBING - GAS PRESSURE TEST | WLAHR | Approved | IVRS - Inspection :* |
01/13/2009 | FRAMING | WLAHR | Approved | IVRS - Inspection :* |
01/13/2009 | MECHANICAL - INTERMEDIATE | WLAHR | Approved | IVRS - Inspection :* |
01/13/2009 | PLUMBING - INTERMEDIATE | WLAHR | Approved | IVRS - Inspection :* |
01/13/2009 | ELECTRIC - INTERMEDIATE | WLAHR | Approved | IVRS - Inspection :* |
01/20/2009 | SHEET ROCK NAILING | WLAHR | Approved | IVRS - Inspection :* |
02/19/2009 | MECHANICAL - FINAL | WLAHR | Approved | IVRS - Inspection :* |
02/19/2009 | PLUMBING - FINAL | WLAHR | Approved | IVRS - Inspection :* |
02/20/2009 | OUTDOOR LIGHTING FINAL | RFREIDIN | Approved | |
02/20/2009 | PLUMBING - GAS PRESS TEST FNL | WLAHR | Approved | |
02/20/2009 | ELECTRIC - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
02/20/2009 | BUILDING - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |