Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address NEW:
1880 W BLUEBERRY LN
Apply Date:
11/25/2008
Applicant:
N/A
Description:
ADDITION:CARPORT

Permit Reviews

Permit Number - T08CM03777
Permit Status: Final
Permit Description: ADDITION:CARPORT
Start Date Submittal Complete Date Status  
11/25/2008 RESIDENTIAL BLDG/ZONING/ENGINE/NPPO 11/26/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM03777
Permit Status: Final
Permit Description: ADDITION:CARPORT
Total Outstanding Activity Conditions - 1
Date Name
11/25/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T08CM03777
Permit Description: ADDITION:CARPORT
Total Completed Inspections - 9
Date Description Inspector Results Comments
12/11/2008 EXT METAL CLIPS/EXT SHEATHING CRUIZ Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) 2 X 8 RAFTERS CALL FOR 24" ON CENTER-SOME ARE 27" & 28"
2) NEED TO EXPOSE COLUMN FOOTERS, TO VERIFY FOOTER DEPTH AND WIDTH
3) NEED TO OPEN UP SOUTHEAST CORNER TOP-TO SEE CONNECTION FOR 4" X 6" POST TO 4" X 5" COLUMN
4) NORTH EAST CORNER FOOTER NEEDS TO BE INSPECTED TO SEE IF FOOTER IS UNDER POST OR ANCHOR WALL
5) LETTER FOR VARIANCE ON SET BACK, NEEDS TO HAVE CITY STAMPED APPROVAL
6) THE IVR MESSAGE MACHINE WAS DOWN THIS MORNING DUE TO COMPUTER MALFUNCTION. I WAS UNABLE TO RETREIVE ANY MESSAGE. I APOLOGIZE FOR THE INCONVENIENCE
12/15/2008 EXCAVATION/LAYOUT REBAR & ZON CRUIZ Approved IVRS - Inspection :*
01/14/2009 ROOF NAILING CRUIZ Approved IVRS - Inspection :*
01/14/2009 FRAMING CRUIZ Approved IVRS - Inspection :*
01/20/2009 ELECTRIC - OUTDOOR LIGHTING CRUIZ Approved IVRS - Inspection :*
01/20/2009 ELECTRIC - INTERMEDIATE CRUIZ Approved IVRS - Inspection :*
01/20/2009 ELECTRIC - FINAL CRUIZ Approved IVRS - Inspection :*
01/20/2009 BUILDING - FINAL CRUIZ Approved IVRS - Inspection :*
01/21/2009 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
001__1.TIF CONSTRPLANS VIEW
002__2.TIF CONSTRPLANS VIEW
003__3.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW