Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
COMMERCIAL ALTERATION
Apply Date:
09/12/2008
Applicant:
N/A
Description:
TI:SHELL
Contractors:
  • TRIUMPH BUILDERS SOUTHWEST LLC *C*

Permit Reviews

Permit Number - T08CM03087
Permit Status: Final
Permit Description: TI:SHELL
Start Date Submittal Complete Date Status  
02/03/2009 3RD PARTY REVIEW-REVISION/OTHER 02/23/2009 COMPLETED Review Details
09/12/2008 PLANS OK TO SUBMIT - COMM 09/17/2008 COMPLETED Review Details
09/17/2008 3RD PARTY REVIEW-COMMERCIAL TI 12/03/2008 COMPLETED Review Details
12/03/2008 POST 3RD PARTY REVIEW 12/08/2008 COMPLETED Review Details
12/08/2008 3RD PARTY REVIEW-REVISION/OTHER 12/12/2008 COMPLETED Review Details
12/12/2008 3RD PARTY REVIEW-REVISION/OTHER 12/15/2008 COMPLETED Review Details
12/15/2008 RESUBMITTAL 12/19/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM03087
Permit Status: Final
Permit Description: TI:SHELL
Total Outstanding Activity Conditions - 1
Date Name
09/12/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T08CM03087
Permit Description: TI:SHELL
Total Completed Inspections - 27
Date Description Inspector Results Comments
01/20/2009 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
01/28/2009 PLUMBING - PRE SLAB BBENEDON Approved IVRS - Inspection :*
02/10/2009 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
OK TO POUR; WIRE MESH, DOWELED @ 48" O.C.
02/24/2009 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
OK TO COVER HARD CEILINGS
02/27/2009 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
03/02/2009 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
04/09/2009 REINFORCED MASONRY PRE-GROUT JBURGE Approved IVRS - Inspection :*
SCREEN WALLS FOR MECHANICAL EQUIPMENT @ 8'
OK TO GROUT AND CAP
04/27/2009 ELECTRIC - INTERMEDIATE RMORENO Approved IVRS - Inspection :*
SECOND PHASE WALLS FOR OFFICES OK
04/27/2009 FRAMING JBURGE Approved IVRS - Inspection :*
SHELL FRAMING IS COMPLETE
04/28/2009 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
04/28/2009 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
05/05/2009 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
OK TO TAPE EXTERIOR WALLS
05/08/2009 PLUMBING - YARD WTR LINE/TEST BBENEDON Approved IVRS - Inspection :*
06/25/2009 NPPO - FINAL ACONNOR Approved N/A
06/25/2009 LANDSCAPE - FINAL ACONNOR Approved N/A
06/25/2009 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
06/25/2009 RIGHT OF WAY - FINAL PWHIDDON Approved PER EMAIL
06/29/2009 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
06/29/2009 FIRE SPKLR - FINAL LTHOMAS Approved
06/29/2009 FIRE - FINAL LTHOMAS Approved
07/17/2009 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
1) AIR BALANCE-OK
2) OK FOR FINAL
08/12/2009 ELECTRIC - ABOVE CEILING RMORENO Approved
08/12/2009 ELECTRIC - FINAL RMORENO Approved IVRS - Inspection :*
08/21/2009 ENGINEERING - FINAL DROBERTS Approved ALL PREVIOUS COMMENTS HAVE BEEN CLEARED AT THIS TIME.
08/21/2009 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
08/21/2009 STEM WALL/RETAINING WALL JBURGE Approved IVRS - Inspection :*
08/21/2009 EXCAVATION/LAYOUT REBAR & ZON JBURGE Approved IVRS - Inspection :*

Documents

File Name Document Type  
SHELLBUILDING.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW
001_A1.0.TIF CONSTRPLANS VIEW
002_A1.1.TIF CONSTRPLANS VIEW
003_A2.0.TIF CONSTRPLANS VIEW
004_A3.0.TIF CONSTRPLANS VIEW
005_A4.0.TIF CONSTRPLANS VIEW
006_A7.0.TIF CONSTRPLANS VIEW
007_S1.0.TIF CONSTRPLANS VIEW
008_S2.0.TIF CONSTRPLANS VIEW
009_M1.0.TIF CONSTRPLANS VIEW
010_M2.0.TIF CONSTRPLANS VIEW
011_M3.0.TIF CONSTRPLANS VIEW
012_M4.0.TIF CONSTRPLANS VIEW
013_M5.0.TIF CONSTRPLANS VIEW
014_P1.0.TIF CONSTRPLANS VIEW
015_P2.0.TIF CONSTRPLANS VIEW
016_P3.0.TIF CONSTRPLANS VIEW
017_E1.0.TIF CONSTRPLANS VIEW
018_E2.0.TIF CONSTRPLANS VIEW
019_E3.0.TIF CONSTRPLANS VIEW
020_E4.0.TIF CONSTRPLANS VIEW
021_E5.0.TIF CONSTRPLANS VIEW
001_E0.1.TIF CONSTRPLANS VIEW