Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T08CM02555
Permit Details
Apply Date:
07/24/2008
Applicant:
D R HORTON HOMES *C
Description:
SFR:TD16-90-69 T07-M0060
Contractors:
- D R HORTON HOMES *C
Permit Reviews
Permit Number - T08CM02555
Permit Status: C of o
Permit Description: SFR:TD16-90-69 T07-M0060
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/24/2008 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 07/25/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM02555
Permit Status: C of o
Permit Description: SFR:TD16-90-69 T07-M0060
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/24/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T08CM02555
Permit Description: SFR:TD16-90-69 T07-M0060
Total Completed Inspections - 26
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/13/2008 | PLUMBING - YARD WTR LINE/TEST | EDURAZO | Approved | H20 LINE NOT CONNECTED TO METER |
08/13/2008 | PLUMBING - SEWER HCS CONNECT | EDURAZO | Approved | IVRS - Inspection :* |
08/13/2008 | PLUMBING - ROUGH, SOIL | EDURAZO | Approved | IVRS - Inspection :* |
08/18/2008 | ELECTRIC - UFER | RCAMACHO | Approved | IVRS - Inspection :* |
08/18/2008 | STEM WALL/RETAINING WALL | RCAMACHO | Approved | IVRS - Inspection :* |
08/18/2008 | EXCAVATION/LAYOUT REBAR & ZON | RCAMACHO | Approved | IVRS - Inspection :* |
08/19/2008 | PLUMBING - PRE SLAB | EDURAZO | Approved | IVRS - Inspection :* |
08/19/2008 | BUILDING PRE-SLAB | EDURAZO | Approved | IVRS - Inspection :* |
09/03/2008 | ROOF NAILING | CRUIZ | Approved | IVRS - Inspection :* |
09/03/2008 | EXT METAL CLIPS/EXT SHEATHING | CRUIZ | Approved | IVRS - Inspection :* |
10/02/2008 | PLUMBING - GAS PRESSURE TEST | WNORTH | Approved | IVRS - Inspection :* |
10/08/2008 | MECHANICAL - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
10/08/2008 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
10/08/2008 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
10/08/2008 | STUCCO MESH | RCAMACHO | Approved | IVRS - Inspection :* |
10/09/2008 | FRAMING | EDURAZO | Approved | IVRS - Inspection :* |
10/14/2008 | SHEET ROCK NAILING | WLAHR | Approved | IVRS - Inspection :* |
10/22/2008 | ELECTRIC - TEMPORARY SERVICE | CRUIZ | Approved | IVRS - Inspection :* |
10/22/2008 | ELECTRIC - CABLE DROP | CRUIZ | Approved | IVRS - Inspection :* |
10/23/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER C. RUIZ |
10/27/2008 | ASSURANCE | MCARREON | Approved | |
12/24/2008 | BUILDING - FINAL | EDURAZO | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) TRADES NOT COMPLETE |
12/24/2008 | MECHANICAL - FINAL | EDURAZO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/24/2008 | PLUMBING - FINAL | EDURAZO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/24/2008 | ELECTRIC - FINAL | EDURAZO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
01/06/2009 | PERMIT FINALED | JWEATHER | Approved |