Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
06/04/2008
Applicant:
MERITAGE HOMES CONSTRUCTION INC *C
Description:
SFR:MERI001547
Contractors:
  • MERITAGE HOMES CONSTRUCTION INC *C

Permit Reviews

Permit Number - T08CM01914
Permit Status: C of o
Permit Description: SFR:MERI001547
Start Date Submittal Complete Date Status  
06/04/2008 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 06/05/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM01914
Permit Status: C of o
Permit Description: SFR:MERI001547
Total Outstanding Activity Conditions - 1
Date Name
06/04/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T08CM01914
Permit Description: SFR:MERI001547
Total Completed Inspections - 25
Date Description Inspector Results Comments
06/24/2008 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection :*
06/24/2008 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection :*
06/24/2008 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection :*
07/01/2008 BUILDING PRE-SLAB WLAHR Approved IVRS - Inspection :*
07/01/2008 EXCAVATION/LAYOUT REBAR & ZON WLAHR Approved IVRS - Inspection :*
07/23/2008 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection :*
1) EAST END TRUSS GABLE SHIM UNDER EACH VERT CONTINOUS BEARING REQUIRED NOTCHED 2 X 4 TOP CHORD
2) SUPPORT ROOF REAR PORCH TO MAIN ROOF JOINT
07/23/2008 ROOF NAILING RFREIDIN Approved IVRS - Inspection :*
07/28/2008 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved IVRS - Inspection :*
07/29/2008 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER R. FREIDINGER
08/11/2008 ELECTRIC - UFER WNORTH Approved IVRS - Inspection :*
08/11/2008 PLUMBING - GAS PRESSURE TEST WNORTH Approved IVRS - Inspection :*
08/11/2008 U VALUE FOR WINDOW WNORTH Approved IVRS - Inspection :*
08/11/2008 STUCCO MESH WNORTH Approved IVRS - Inspection :*
08/11/2008 FRAMING WNORTH Approved IVRS - Inspection :*
08/12/2008 MECHANICAL - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
08/12/2008 PLUMBING - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
08/12/2008 ELECTRIC - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
08/21/2008 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection :*
10/07/2008 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection :*
10/07/2008 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection :*
10/09/2008 ELECTRIC - OUTDOOR LIGHTING RFREIDIN Approved
10/09/2008 ELECTRIC - UNDERGROUND RFREIDIN Approved
10/09/2008 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection :*
10/09/2008 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection :*
10/10/2008 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
C OF O_10-10-2008.TIF CERT OF OCC VIEW
None DOCUMENTS VIEW
None CONSTRPLANS VIEW