Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T08CM01564
Permit Details
Apply Date:
05/14/2008
Applicant:
N/A
Description:
NEW APARTMENT BUILDING #4
Contractors:
- TOFEL CONSTRUCTION
Permit Reviews
Permit Number - T08CM01564
Permit Status: C of o
Permit Description: NEW APARTMENT BUILDING #4
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/04/2009 | RESUBMITTAL | 09/28/2009 | COMPLETED |
05/14/2008 | PLANS OK TO SUBMIT - 3RD PARTY | 05/14/2008 | COMPLETED |
05/14/2008 | 3RD PARTY REVIEW-COMMERCIAL | 09/22/2008 | COMPLETED |
09/22/2008 | POST 3RD PARTY REVIEW | 02/04/2009 | COMPLETED |
10/06/2009 | REVISION - - 1ST | 11/04/2009 | COMPLETED |
11/04/2009 | REVISION - - 1ST | 11/10/2009 | COMPLETED |
11/10/2009 | REVISION - - 1ST | 11/19/2009 | COMPLETED |
11/19/2009 | REVISION - - 2ND | 11/19/2009 | COMPLETED |
11/19/2009 | REVISION - - 3RD | 08/11/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM01564
Permit Status: C of o
Permit Description: NEW APARTMENT BUILDING #4
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/14/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T08CM01564
Permit Description: NEW APARTMENT BUILDING #4
Total Completed Inspections - 34
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/05/2009 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* 1) PVC DWV UNDERGROUND OK TO COVER 2) HCS MADE WITH A HUB SET |
11/13/2009 | ELECTRIC - PROGRESS | RJIROUDE | Approved | IVRS - Inspection :* 1) #4 TO REBAR IN FOOTING |
11/13/2009 | ELECTRIC - UFER | RJIROUDE | Approved | IVRS - Inspection :* |
11/16/2009 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection :* 1) UNDER SLAB T & P RELIEF AND CONDENSATE DRAIN OK TO COVER |
11/16/2009 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | IVRS - Inspection :* 1) CONTINOUS FOOTINGS-OK TO POUR |
11/16/2009 | BUILDING PRE-SLAB | JBURGE | Approved | IVRS - Inspection :* 1) POST TENSION SYSTEM-DETAIL #1 PAGE S2.3.1-OK TO POUR SLAB |
01/11/2010 | ROOF NAILING | JBURGE | Approved | OK TO DRY IN |
01/11/2010 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
02/17/2010 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* |
03/08/2010 | FRAMING | JBURGE | Approved | IVRS - Inspection :* 1) OK TO SHEETROCK THROUGHOUT |
04/09/2010 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
05/05/2010 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* |
06/16/2010 | ELECTRIC - CABLE DROP | DSANTACR | Approved | IVRS - Inspection :* |
07/29/2010 | OUTDOOR LIGHTING FINAL | RMORENO | Approved | |
07/29/2010 | ELECTRIC - RECONNECT | RMORENO | Approved | |
07/29/2010 | ELECTRIC - CONSTRUCTION POWER | RMORENO | Approved | |
07/29/2010 | ELECTRIC - OUTDOOR LIGHTING | RMORENO | Approved | |
07/29/2010 | ELECTRIC - ABOVE CEILING | RMORENO | Approved | |
07/29/2010 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
07/29/2010 | MECHANICAL - PROGRESS | MRAMBER | Approved | IVRS - Inspection :* |
07/29/2010 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
07/29/2010 | ELECTRIC - FINAL | RMORENO | Approved | IVRS - Inspection :* |
08/03/2010 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | |
08/03/2010 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | |
08/03/2010 | PLUMBING - ABOVE CEILING | RMYERS | Approved | |
08/03/2010 | PLUMBING - INTERMEDIATE | RMYERS | Approved | |
08/03/2010 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* |
08/09/2010 | FIRE - ALARM FINAL | LTHOMAS | Approved | |
08/09/2010 | FIRE - FINAL | LTHOMAS | Approved | |
08/11/2010 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
08/11/2010 | BUILDING - PROGRESS | JBURGE | Approved | |
08/11/2010 | U VALUE FOR WINDOW | JBURGE | Approved | |
08/11/2010 | BUILDING ABOVE CEILING | JBURGE | Approved | |
08/11/2010 | EXT METAL CLIPS/EXT SHEATHING | JBURGE | Approved |