Permit: T08CM01318
Permit Details
Apply Date:
04/24/2008
Applicant:
N/A
Description:
REPAIR: PLUMBING, ELECTRICAL T08DV02006 ADD: SHOWER R1: UPGRADE PANEL 5-7-08
Permit Reviews
Permit Number - T08CM01318
Permit Status: Final
Permit Description: REPAIR: PLUMBING, ELECTRICAL T08DV02006
ADD: SHOWER
R1: UPGRADE PANEL 5-7-08
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/24/2008 | RESIDENTIAL BLDG/ZONING/ENGINE/WWM | 04/24/2008 | COMPLETED |
| 05/07/2008 | REVISION - - 1ST | 05/07/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM01318
Permit Status: Final
Permit Description: REPAIR: PLUMBING, ELECTRICAL T08DV02006
ADD: SHOWER
R1: UPGRADE PANEL 5-7-08
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/24/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T08CM01318
Permit Description: REPAIR: PLUMBING, ELECTRICAL T08DV02006
ADD: SHOWER
R1: UPGRADE PANEL 5-7-08
Total Completed Inspections - 11
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/17/2008 | PLUMBING - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. CANNOT USE VENT 90s ON DRAINS 2. VENTS NEED TO COME OFF AFTER TRAPS 3. CANNOT RUN 2 DRAINS THRU 1 TRAP 4. RECOMMEND USING QUALIFIED PLUMBER 5. SHOWER REQUIRES 2" DRAIN 6. WHAT SIZE ROMEX TO SUB-PANEL? |
| 10/17/2008 | ELECTRIC - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* 1. CANNOT USE VENT 90s ON DRAINS 2. VENTS NEED TO COME OFF AFTER TRAPS 3. CANNOT RUN 2 DRAINS THRU 1 TRAP 4. RECOMMEND USING QUALIFIED PLUMBER 5. SHOWER REQUIRES 2" DRAIN 6. WHAT SIZE ROMEX TO SUB-PANEL? |
| 10/17/2008 | FRAMING | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. CANNOT USE VENT 90s ON DRAINS 2. VENTS NEED TO COME OFF AFTER TRAPS 3. CANNOT RUN 2 DRAINS THRU 1 TRAP 4. RECOMMEND USING QUALIFIED PLUMBER 5. SHOWER REQUIRES 2" DRAIN 6. WHAT SIZE ROMEX TO SUB-PANEL? |
| 10/17/2008 | PLUMBING - ROUGH, SOIL | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 02/18/2009 | SHEET ROCK NAILING | DWALKER | Approved | IVRS - Inspection :* |
| 07/31/2009 | ELECTRIC - TEMPORARY SERVICE | DQUINN | Approved | IVRS - Inspection :* |
| 07/31/2009 | ELECTRIC - CABLE DROP | DQUINN | Approved | IVRS - Inspection :* |
| 12/23/2009 | PLUMBING - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 12/23/2009 | ELECTRIC - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 12/23/2009 | BUILDING - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 12/24/2009 | PERMIT FINALED | JWEATHER | Approved |