Permit: T08CM01084
Permit Details
Apply Date:
04/04/2008
Applicant:
N/A
Description:
ADDITION:BEDROOM & STORAGE R1: ADDING A FOOT TO SIZE OF ROOM ADDITION
Permit Reviews
Permit Number - T08CM01084
Permit Status: Expired
Permit Description: ADDITION:BEDROOM & STORAGE
R1: ADDING A FOOT TO SIZE OF ROOM ADDITION
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/04/2008 | RESIDENTIAL BLDG/ZONING/ENGINE/NPPO | 04/04/2008 | COMPLETED |
| 08/11/2008 | REVISION - - 1ST | 08/14/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM01084
Permit Status: Expired
Permit Description: ADDITION:BEDROOM & STORAGE
R1: ADDING A FOOT TO SIZE OF ROOM ADDITION
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/04/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T08CM01084
Permite Description: ADDITION:BEDROOM & STORAGE
R1: ADDING A FOOT TO SIZE OF ROOM ADDITION
Total Outstanding Inspections - 7
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| U VALUE FOR WINDOW | N/A | Not Inspected | ||
| SHEET ROCK NAILING | N/A | Not Inspected | ||
| BUILDING - FINAL | N/A | Not Inspected | ||
| ELECTRIC - FINAL | N/A | Not Inspected | ||
| 12/12/2008 | FRAMING | N/A | Partial Approval | IVRS - Inspection :* 1) PENDING ALL TRADES 2) PROVIDE SMOKE DETECTORS 3) TERMINATE ROMEX IN BOXES SECURE 8" FROM BOX 4) SECURE LATHE 6" ON CENTER PORCH TOP PLATE 5) ALL TOP AND BOTTOM PLATES 6" ON CENTER 6) REINFORCE WINDOW 7) MAKE UP ALL SWITCHES PIG TAIL GROUNDS 8) GROUND METAL BOXES 9) PROVIDE ROMEX CONNECTORS TO METAL BOXES 10) INSTALL ROMEX IN APPROVED BOX PORCH 11) MISSING SCREWS CEILING FAN BOX |
| 12/12/2008 | STUCCO MESH | N/A | Partial Approval | IVRS - Inspection :* |
| 12/12/2008 | ELECTRIC - INTERMEDIATE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
Completed Inspections
Permit Status: Expired
Permit Number: T08CM01084
Permit Description: ADDITION:BEDROOM & STORAGE
R1: ADDING A FOOT TO SIZE OF ROOM ADDITION
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/10/2008 | BUILDING PRE-SLAB | EDURAZO | Approved | IVRS - Inspection :* |
| 06/10/2008 | EXCAVATION/LAYOUT REBAR & ZON | EDURAZO | Approved | IVRS - Inspection :* |
| 09/29/2008 | ROOF NAILING | DQUINN | Approved | IVRS - Inspection :* |
| 09/29/2008 | EXT METAL CLIPS/EXT SHEATHING | DQUINN | Approved | IVRS - Inspection :* |