Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T08CM00519
Permit Details
Apply Date:
02/14/2008
Applicant:
VELASCO JOSE JR & VALDEZ BLANCA S JT/RS
Description:
ADDITION:BEDROOM AND BATHROOM
Permit Reviews
Permit Number - T08CM00519
Permit Status: Closed
Permit Description: ADDITION:BEDROOM AND BATHROOM
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/14/2008 | RESIDENTIAL BLDG/ZONING/ENGINE/WWM | 02/19/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM00519
Permit Status: Closed
Permit Description: ADDITION:BEDROOM AND BATHROOM
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
02/14/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T08CM00519
Permite Description: ADDITION:BEDROOM AND BATHROOM
Total Outstanding Inspections - 5
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
BUILDING - FINAL | N/A | Not Inspected | ||
ELECTRIC - CABLE DROP | N/A | Not Inspected | ||
ELECTRIC - FINAL | N/A | Not Inspected | ||
PLUMBING - FINAL | N/A | Not Inspected | ||
MECHANICAL - FINAL | N/A | Not Inspected |
Completed Inspections
Permit Status: Closed
Permit Number: T08CM00519
Permit Description: ADDITION:BEDROOM AND BATHROOM
Total Completed Inspections - 15
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/29/2008 | PLUMBING - SEWER HCS CONNECT | EDURAZO | Approved | IVRS - Inspection :* |
02/29/2008 | PLUMBING - ROUGH, SOIL | EDURAZO | Approved | IVRS - Inspection :* |
02/29/2008 | BUILDING PRE-SLAB | EDURAZO | Approved | IVRS - Inspection :* |
02/29/2008 | EXCAVATION/LAYOUT REBAR & ZON | EDURAZO | Approved | IVRS - Inspection :* |
03/12/2008 | PLUMBING - YARD WTR LINE/TEST | EDURAZO | Approved | IVRS - Inspection :* |
03/18/2008 | ROOF NAILING | EDURAZO | Approved | IVRS - Inspection :* |
04/01/2008 | ELECTRIC - UFER | RFREIDIN | Approved | IVRS - Inspection :* GRID RODS, NO UFER 1. VENTS THRU ROOF NOT DONE 2. TUB DRAIN NOT CONNECTED, FILL FOR TEST 3. JACUZZI NEEDS TO BE ON SEPARATE CIRCUIT, GFCI PROTECTED 4. WASHER REQS A PEE TRAP/3 CLEAN OUT 5. BATHROOM ROMEX CUT DRILLED PEX HOLE AT TOP PLATE 6. SECURE ALL PIPES & WIRES, NAIL PROTECTION NEEDED 7. CAP OFF OLD SEWER LINES 8. BEDROOM WINDOW TO SMALL FOR EMERGENCY EGRESS 24" HIGH 20" WIDE 9. SMOKE DETECTOR REQ. BEDROOM 10. OLD PORCH LIGHT IF STILL HOT MUST BE ACCESSIBLE |
04/01/2008 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | IVRS - Inspection :* |
05/06/2008 | U VALUE FOR WINDOW | RFREIDIN | Approved | IVRS - Inspection :* |
05/06/2008 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
05/06/2008 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
05/06/2008 | FRAMING | RFREIDIN | Approved | IVRS - Inspection :* |
05/09/2008 | PLUMBING - INTERMEDIATE | EDURAZO | Approved | IVRS - Inspection :* |
07/09/2008 | STUCCO MESH | RFREIDIN | Approved | |
11/25/2008 | SHEET ROCK NAILING | WLAHR | Approved | IVRS - Inspection :* 1) TOY ROOM AND BEDROOM OK 2) BATHROOM NOT READY |