Permit: T08CM00374
Permit Details
Status:
Final
Type:
SINGLE FAMILY ALTERATION
Address:
1537 N EL RIO DR
Address NEW:
1537 N EL RIO DR
Apply Date:
02/04/2008
Applicant:
CASTILLO JOAQUIN
Description:
REPAIRS:GENERAL :UPGRADE ELECTRIC 100AMP TO 200AMP R1: PROVIDE ELECTRICAL PLAN 7-14-08 R2: OVERHEAD TO UNDERGROUND WAIVER R3 BATHROOM PLUMBING
Outstanding Activity Conditions
Permit Number - T08CM00374
Permit Status: Final
Permit Description: REPAIRS:GENERAL :UPGRADE ELECTRIC 100AMP TO 200AMP
R1: PROVIDE ELECTRICAL PLAN 7-14-08
R2: OVERHEAD TO UNDERGROUND WAIVER
R3 BATHROOM PLUMBING
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/04/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T08CM00374
Permit Description: REPAIRS:GENERAL :UPGRADE ELECTRIC 100AMP TO 200AMP
R1: PROVIDE ELECTRICAL PLAN 7-14-08
R2: OVERHEAD TO UNDERGROUND WAIVER
R3 BATHROOM PLUMBING
Total Completed Inspections - 11
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/09/2008 | U VALUE FOR WINDOW | CRUIZ | Approved | IVRS - Inspection :* |
| 09/11/2008 | SHEET ROCK NAILING | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) ALL CONDUCTOR WIRING IN MASONRY MUST BE SLEEVED OR APPROVED FOR DIRECT APPLICATION TO MASONRY 2) NAILING ON OUTSIDE SHEATHING NEEDS TO BE 6" ON EDGES ALSO A MOISTURE BARRIER, NEEDS TO BE INSTALLED BEFORE SHEATHING IS INSTALLED 3) NAILS NEED TO BE RUST PROOF 4) ALL JUNCTION BOXES MUST BE VISIBLE AND ACCESSIBLE 5) NEED TO GROUND ALL METAL BOXES 6) SERVICE PANEL NEEDS TO BE SECURED IN A APPROVED MANNER 7) RISER WILL NEED TO BE BRACED WITH UL LISTED BRACKETS 8) ALL SMOKIES WILL NEED TO BE CONNECTED AND ON A ARC-FAULT BREAKER 9) SOLE PLATES WILL NEED ANCHOR BOLTS 10) NEED PROTECTION PLATES ON NEW FRAMING FOR WIRING |
| 09/11/2008 | ELECTRIC - SERVICE UPGRADE | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 10/13/2008 | ELECTRIC - INTERMEDIATE | CRUIZ | Approved | IVRS - Inspection :* |
| 10/13/2008 | EXT METAL CLIPS/EXT SHEATHING | CRUIZ | Approved | IVRS - Inspection :* |
| 03/09/2009 | ELECTRIC - RECONNECT | CRUIZ | Approved | IVRS - Inspection :* |
| 03/09/2009 | TEP CLEARANCE - PM | JWEATHER | Approved | INCR/RECONNECT CLEARED PER C. RUIZ |
| 05/11/2009 | PLUMBING - FINAL | CRUIZ | Approved | IVRS - Inspection :* |
| 05/12/2009 | ELECTRIC - FINAL | CRUIZ | Approved | IVRS - Inspection :* |
| 05/12/2009 | BUILDING - FINAL | CRUIZ | Approved | IVRS - Inspection :* |
| 05/13/2009 | PERMIT FINALED | JWEATHER | Approved |