Permit Details

Status:
Final
Type:
SINGLE FAMILY ALTERATION
Address:
1537 N EL RIO DR
Address NEW:
1537 N EL RIO DR
Apply Date:
02/04/2008
Applicant:
CASTILLO JOAQUIN
Description:
REPAIRS:GENERAL :UPGRADE ELECTRIC 100AMP TO 200AMP R1: PROVIDE ELECTRICAL PLAN 7-14-08 R2: OVERHEAD TO UNDERGROUND WAIVER R3 BATHROOM PLUMBING

Outstanding Activity Conditions

Permit Number - T08CM00374
Permit Status: Final
Permit Description: REPAIRS:GENERAL :UPGRADE ELECTRIC 100AMP TO 200AMP R1: PROVIDE ELECTRICAL PLAN 7-14-08 R2: OVERHEAD TO UNDERGROUND WAIVER R3 BATHROOM PLUMBING
Total Outstanding Activity Conditions - 1
Date Name
02/04/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T08CM00374
Permit Description: REPAIRS:GENERAL :UPGRADE ELECTRIC 100AMP TO 200AMP R1: PROVIDE ELECTRICAL PLAN 7-14-08 R2: OVERHEAD TO UNDERGROUND WAIVER R3 BATHROOM PLUMBING
Total Completed Inspections - 11
Date Description Inspector Results Comments
07/09/2008 U VALUE FOR WINDOW CRUIZ Approved IVRS - Inspection :*
09/11/2008 SHEET ROCK NAILING CRUIZ Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) ALL CONDUCTOR WIRING IN MASONRY MUST BE SLEEVED OR APPROVED FOR DIRECT APPLICATION TO MASONRY
2) NAILING ON OUTSIDE SHEATHING NEEDS TO BE 6" ON EDGES ALSO A MOISTURE BARRIER, NEEDS TO BE INSTALLED BEFORE SHEATHING IS INSTALLED
3) NAILS NEED TO BE RUST PROOF
4) ALL JUNCTION BOXES MUST BE VISIBLE AND ACCESSIBLE
5) NEED TO GROUND ALL METAL BOXES
6) SERVICE PANEL NEEDS TO BE SECURED IN A APPROVED MANNER
7) RISER WILL NEED TO BE BRACED WITH UL LISTED BRACKETS
8) ALL SMOKIES WILL NEED TO BE CONNECTED AND ON A ARC-FAULT BREAKER
9) SOLE PLATES WILL NEED ANCHOR BOLTS
10) NEED PROTECTION PLATES ON NEW FRAMING FOR WIRING
09/11/2008 ELECTRIC - SERVICE UPGRADE CRUIZ Approved IVRS - Inspection :
See detailed listing on site.| 999*
10/13/2008 ELECTRIC - INTERMEDIATE CRUIZ Approved IVRS - Inspection :*
10/13/2008 EXT METAL CLIPS/EXT SHEATHING CRUIZ Approved IVRS - Inspection :*
03/09/2009 ELECTRIC - RECONNECT CRUIZ Approved IVRS - Inspection :*
03/09/2009 TEP CLEARANCE - PM JWEATHER Approved INCR/RECONNECT CLEARED PER C. RUIZ
05/11/2009 PLUMBING - FINAL CRUIZ Approved IVRS - Inspection :*
05/12/2009 ELECTRIC - FINAL CRUIZ Approved IVRS - Inspection :*
05/12/2009 BUILDING - FINAL CRUIZ Approved IVRS - Inspection :*
05/13/2009 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
001__S1.TIF CONSTRPLANS VIEW
002__E1.TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW
None DOCUMENTS VIEW