JON FABULA
Description:
REPLACE:WATER HEATER
Contractors:
- ALL PRO PLUMBING ,
Outstanding Activity Conditions
Permit Number - T07PL01767
Permit Status: Expired
Permit Description: REPLACE:WATER HEATER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/15/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07PL01767
Permite Description: REPLACE:WATER HEATER
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/16/2007 | PLUMBING - GAS PRESS TEST FNL | N/A | Not ready for Inspection | IVRS - Inspection :* |
| 10/16/2007 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* - NEW GAS FLEX REQUIRED - SEDIMENT TRAP REQUIRED - B VENT IS UPSIDE DOWN - SECURE VENT W/GALV SHEETMETAL SCREWS - PROVIDE DIELECTRIC ISOLATORS AT COPPER TO GALV CONNECTIONS - SECURE T&P, CORRECT SLOPE - IF INSPECTION IS FOR GAS ALSO, IDENTIFY PIPING. - PROVIDE TEST AND ACCESS TO ALL APPLIANCES |