Permit: T07PL01700
Permit Details
Apply Date:
10/03/2007
Applicant:
CARO EDDIE & OFELIA M CP/RS
Description:
INSTALL:NEW GAS LINE
Outstanding Activity Conditions
Permit Number - T07PL01700
Permit Status: Final
Permit Description: INSTALL:NEW GAS LINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/03/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07PL01700
Permit Description: INSTALL:NEW GAS LINE
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/18/2007 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* 1. SHALL PROVIDE BONDING FOR BUILDING GAS PIPING 2. SHALL SECURE & SUPPORT PIPING AT DROP AT WATER HEATER/FURNACE LOCATION 3. SHALL PRIME, THEN 10 MIL. TAPE ALL TOOL MARKS AND FITTING BELOW GRADE ON PIPING SYSTEM. GAS CARD AT METER SW GAS 889-1888 |
| 10/18/2007 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* |
| 10/18/2007 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* |
| 01/23/2008 | PERMIT FINALED | BFLORES | Approved |