Permit: T07PL01059
Permit Details
Status:
Closed
Type:
SINGLE FAMILY OTHER
Address:
751 N SUNSTREAM LN
Address NEW:
751 N SUNSTREAM LN
Apply Date:
06/14/2007
Applicant:
WALTER VIRGINIA
Description:
Replace 40 gallon water heater.
Contractors:
- RITE WAY VENTILATING CO , *C
Outstanding Activity Conditions
Permit Number - T07PL01059
Permit Status: Closed
Permit Description: Replace 40 gallon water heater.
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/14/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Closed
Permit Number: T07PL01059
Permit Description: Replace 40 gallon water heater.
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/23/2007 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. SHALL MAKE UP VENT CONNECTION CORRECTLY TO DRAFT HOOD. 2. SHALL PROVIDE SEDIMENT TRAP AT GAS ENTRY 3. SHALL PROVIDE FULLSIZE RIDGID PIPING FOR T&P RELIEF DRAIN (NO FLEX) T&P TO GRAVITY DRAIN TO DAYLIGHT TERMINATING 6"-24" FROM FINISH GRADE 4. SHALL PROVIDE CORRECT CONNECTION FITTING FOR JUNCTION OF FURNACE & WATER HEATER VENT. |