Permit: T07PL00620
Permit Details
Apply Date:
04/06/2007
Applicant:
JAIME ESTRADA
Description:
GAS LINE:REPLACE
Permit Reviews
Permit Number - T07PL00620
Permit Status: Expired
Permit Description: GAS LINE:REPLACE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/06/2007 | PLUMBING | 04/06/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07PL00620
Permit Status: Expired
Permit Description: GAS LINE:REPLACE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/06/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07PL00620
Permite Description: GAS LINE:REPLACE
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/17/2007 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* GAS CARD AT METER 1. SEAL GAS PIPING PENETRATION INTO BUILDING AND T&P DRAIN PENETRATION OUT OF BUILDING 2. ROTATE ADJUSTABLE 90 DEG. ON FURNACE VENTING TO PROVIDE FOR 60 DEG. OFFSET IN VENT PIPING AND PROVIDE CORRECT SUPPORT OF WATER HEATER/FURNACE VENTS ON EXTERIOR WITH MINIMUM 1" CLEARANCE FROM COMBUSTIBLES. |
Completed Inspections
Permit Status: Expired
Permit Number: T07PL00620
Permit Description: GAS LINE:REPLACE
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/17/2007 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* |