Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
6933 E CALLE CANIS
Apply Date:
03/22/2007
Applicant:
ARIZONA PLUMBING SERVICES *C
Description:
REPLACE: WATER HEATER (APA)
Contractors:
  • ARIZONA PLUMBING SERVICES *C

Outstanding Activity Conditions

Permit Number - T07PL00536
Permit Status: Expired
Permit Description: REPLACE: WATER HEATER (APA)
Total Outstanding Activity Conditions - 1
Date Name
03/22/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T07PL00536
Permite Description: REPLACE: WATER HEATER (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
04/17/2007 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
1. PROVIDE CITY SIGNED PETITION OF APPEAL FOR ALTERNATE FORM OF TEMPERATURE & PRESSURE RELIEF ON SITE.
2. PROVIDE MINIMUM 100 SQ. INCH UPPER & LOWER COMBUSTION AIR OPENINGS IN UPPER 12" & LOWER 12" OF WATER HEATER ENCLOSURE FOR COMBUSTION AIR FROM INFILTRATION.
3. PROVIDE 3-GALV SCREWS AT EACH JOINT OF WATER HEATER VENT CONNECTOR PIPING.
4. PROVIDE DOUBLE WALL VENT THRU ROOF WITH APPROVED VENT CAP.

Documents

File Name Document Type  
None DOCUMENTS VIEW