Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T07PL00407
Permit Details
Apply Date:
03/06/2007
Applicant:
ARIZONA PLUMBING SERVICES *C
Description:
REPLACE: WATER HEATER (APA)
Contractors:
- ARIZONA PLUMBING SERVICES *C
Outstanding Activity Conditions
Permit Number - T07PL00407
Permit Status: Withdrwn
Permit Description: REPLACE: WATER HEATER (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/06/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Withdrwn
Permit Number: T07PL00407
Permite Description: REPLACE: WATER HEATER (APA)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/27/2007 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE THREE SCREW FOR EACH JOINT FOR FLUE VENT 2. REMOVE TAPE ON FLUE VENT FROM SINGULAR TO DOUBLE WALL 3. RUN FLUE VENT THRU CENTER OF CEILING HOLE THRU ROOF |