Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/29/2007 | SIGN SITE REVIEW | JSONKN | Approved | |
12/13/2007 | SIGN SHOP | RHOLLAND | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. A MARKING LABEL IS NEEDED 600.4 2. FILL UNUSED OPENINGS 3. USE TERMINAL ENDS WITH STRANDED CONDUCTORS 4. SWITCHES TO BE CAPABLE OF BEING LOCKED OUT 5. TIGHTEN LOOSE FITTINGS 6. FLEX CONDUIT BROKEN 7. ONLY ONE CONDUCTOR PER LUG TERMINATION |
12/13/2007 | SIGN ELECTRIC | RHOLLAND | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* |
12/13/2007 | SIGN INSPECTION | JSONKIN | Approved | IVRS - Inspection :* |
03/03/2008 | PERMIT FINALED | BFLORES | Approved |