Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SIGN PERMIT
Apply Date:
08/28/2007
Applicant:
PRECISE SIGN CO ,
Description:
13583
Contractors:
  • PRECISE SIGN CO ,

Outstanding Inspections

Permit Status: Expired
Permit Number: T07OT01941
Permite Description: 13583
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
12/11/2007 SIGN SHOP N/A Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. CORRECTLY FILL OUT MARKING LABEL
2. CONDUCTOR COVERS TO BE PER 310.5(C) CITY AMENDMENTS
3. SUPPORT FLEX 12" & 4' AS PER CODE
4. SUPPORT JUNCTION BOX
5. GROUND JUNCTION BOXES
6. NEED CITY WORKSHEET
12/11/2007 SIGN ELECTRIC N/A Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*

Completed Inspections

Permit Status: Expired
Permit Number: T07OT01941
Permit Description: 13583
Total Completed Inspections - 2
Date Description Inspector Results Comments
08/31/2007 SIGN SITE REVIEW JSONKIN Approved
11/23/2007 SIGN INSPECTION JYBARRA Approved

Documents

File Name Document Type  
PERMITPACKET.PDF SIGNS VIEW
SITEPLAN.PDF SIGNS VIEW
SIGNCONSTPLAN.PDF SIGNS VIEW
None SIGNS VIEW