Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SIGN PERMIT
Apply Date:
08/15/2007
Applicant:
YOUNG ELECTRIC SIGN COMPANY*C
Description:
13525
Contractors:
  • YOUNG ELECTRIC SIGN COMPANY*C

Outstanding Inspections

Permit Status: Expired
Permit Number: T07OT01843
Permite Description: 13525
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
08/11/2010 SIGN SHOP N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED FULL SURFACE CONTACT FOR GROUND LUG 600.7
2) PROTECT LIVE WIRE WITH PASS THRU AND BOND LETTER 1ST "P"
3) NEED MARKING LABEL 600.4
4) 2 PULL BOX SIGNS AND 2 DIRECTIONAL SIGNS NOT ON THIS PERMIT. IS THERE ANOTHER PERMIT ?
08/11/2010 SIGN ELECTRIC N/A Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*

Completed Inspections

Permit Status: Expired
Permit Number: T07OT01843
Permit Description: 13525
Total Completed Inspections - 2
Date Description Inspector Results Comments
08/16/2007 SIGN SITE REVIEW JYBARRA Approved
02/13/2008 SIGN INSPECTION JYBARRA Approved IVRS - Inspection :*

Documents

File Name Document Type  
PERMITPACKET.PDF SIGNS VIEW
SIGNELEVATIONPLAN.PDF SIGNS VIEW
SITEPLAN.PDF SIGNS VIEW