Permit: T07OT00868
Permit Details
Status:
Expired
Type:
COMMERCIAL OTHER
Address:
1250 W SILVERLAKE RD
Address NEW:
1250 W SILVERLAKE RD
Apply Date:
04/12/2007
Applicant:
CINDY SYLVESTER:PIMA COUNTY
Description:
FLOODPLAIN USE PERMIT
Permit Reviews
Permit Number - T07OT00868
Permit Status: Expired
Permit Description: FLOODPLAIN USE PERMIT
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/12/2007 | FLOODPLAIN | 04/30/2007 | COMPLETED |
| 04/26/2007 | RESUBMITTAL | 04/30/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07OT00868
Permit Status: Expired
Permit Description: FLOODPLAIN USE PERMIT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/27/2007 | THE FOLLOWING 11 CONDITIONS APPLY TO THE FLOODPLAIN USE PERMIT T07OT00868: 1) WITHIN 5 (FIVE) DAYS OF ISSUANCE OF THIS PERMIT, AND THROUGH COMPLETION OF THE PROJECT, NOTIFICATION MUST BE POSTED AND MAINTAINED IN A CONSPICUOUS PLACE ON THE JOB SITE STATING "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T07OT00868. 2) FOR DSD ENGINEERING INSPECTIONS, PLEASE CALL 837-9089." 3) THIS PERMIT BECOMES INVALID AND IS SUBJECT TO ADDITIONAL FLOODPLAIN REVIEW, IF ANY REQUIRED DEVELOPMENT PERMIT CHANGES THE CONFIGURATION OF THE IMPROVEMENT, OR, IF THERE IS ANY FURTHER DISTURBANCE WITHIN THE FLOODPLAIN OTHER THAN THAT OUTLINED IN THIS APPLICATION. THIS FLOODPLAIN USE PERMIT MAY BE SUBJECT TO CONDITIONS OR RESTRICTIONS DESIGNED TO REDUCE OR MITIGATE THE POTENTIAL DAMAGE OR HAZARD TO LIFE OR PROPERTY RESULTING FROM DEVELOPMENT WITHIN THE REGULATORY FLOODPLAIN, FLOODWAY OR EROSION HAZARD AREAS AS DETERMINED BY THE PROJECT ENGINEER AND ACCEPTED BY THE CITY OF TUCSON. 4) THIS FLOODPLAIN USE PERMIT AND APPROVED PLANS SHALL BE KEPT IN A READILY ACCESSIBLE LOCATION ON SITE AT ALL TIMES. 5) ANY ADDITIONAL FUTURE DISTURBANCE OF THE FLOODPLAIN SHALL HAVE SEPARATE FLOODPLAIN USE PERMIT APPLICATIONS SUBMITTED TO THIS OFFICE FOR REVIEW AND APPROVAL. 6) EXCEPT AS APPROVED BY THE CITY ENGINEER PRIOR TO THE START OF CONSTRUCTION, DEVELOPMENT UNDER THIS PERMIT SHALL NOT OBSTRUCT, RETARD OR DIVERT THE EXISTING FLOW OF FLOODWATERS FROM OR TO ADJACENT PROPERTIES. 7) ALL WORK SHALL CONFORM TO THE APPROVED SITE PLAN SHEET A0.2 FOR THE ELECTRICAL CONTROLLER AND PUMP INSTALLATION, SEALED BY RICHARD BEACH, RA (4/24/07), WHICH IS MADE PART OF THIS PERMIT. 8) CONTACT ENVIRONMENTAL SERVICES FOR ANY FOUNDATION REQUIREMENTS FOR PROXIMITY TO THE CLOSED 29TH STREET LANDFILL. 9) THERE SHALL BE NO DISTURBANCE OUTSIDE OF LIMITS OF CUT AND FILL AS INDICATED ON PLANS. 10) SPECIAL INSPECTIONS BY A QUALIFIED REGISTRANT ARE REQUIRED FOR THE TOEDOWN CONSTRUCTION / DEPTH, TIE-IN TO EXISTING BANK PROTECTION, AND THE COMPACTION OF BACKFILL. DSD ENGINEERING INSPECTORS SHOULD BE CALLED TO THE SITE DURING THESE SPECIAL INSPECTIONS. REPORTS FROM GEOTECHNICAL ENGINEER AND ENGINEER OF RECORD SHOULD BE SUBMITTED TO THE CITY OF TUCSON FOR RECORDS PRIOR TO CALLING IN FOR THE FINAL DSD FLOODPLAIN INSPECTION BY THE CITY OF TUCSON DEVELOPMENT SERVICES DEPARTMENT. 11) THERE SHALL BE NO STOCKPILING MATERIAL WITHIN THE WEST BRANCH OF THE SANTA CRUZ. |